DS2788E+T&R Maxim Integrated Products, DS2788E+T&R Datasheet - Page 7

IC FUEL GAUGE W/DSP DRV 14TSSOP

DS2788E+T&R

Manufacturer Part Number
DS2788E+T&R
Description
IC FUEL GAUGE W/DSP DRV 14TSSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS2788E+T&R

Function
Fuel, Gas Gauge/Monitor
Battery Type
Lithium-Ion (Li-Ion), Lithium-Polymer (Li-Pol)
Voltage - Supply
2.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
14-TSSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
nection or system shutdown, in which no charge or dis-
charge current flows. A PMOD SLEEP condition transi-
tions back to ACTIVE mode when DQ is pulled high.
The second option for entering SLEEP is an undervolt-
age condition. When the UVEN bit is set, the DS2788
transitions to SLEEP if the voltage on V
V
high logic level for t
occurs when a pack is fully discharged, where loading
on the battery should be minimized. UVEN SLEEP
relieves the battery of the I
cation on DQ resumes.
Note: PMOD and UVEN SLEEP features must be dis-
abled when a battery is charged on an external charger
that does not connect to the DQ pin. PMOD SLEEP can
be used if the charger pulls DQ high. UVEN SLEEP can
be used if the charger toggles DQ. The DS2788
remains in SLEEP and therefore does not measure or
accumulate current when a battery is charged on a
charger that fails to properly drive DQ.
When beginning communication with a DS2788 in
PMOD SLEEP, DQ must be pulled up first and then a
1-Wire reset pulse must be issued by the master. In
UVEN SLEEP, the procedure depends on the state of
DQ when UVEN SLEEP was entered. If DQ was low,
DQ must be pulled up and then a 1-Wire reset pulse
Figure 3. Voltage Register Format
SLEEP
VOLT
MSb
“S”: SIGN BIT(S), “X”: RESERVED
S
(2.45V nominal) and DQ is stable at a low or
2
9
Initiating Communication
2
_______________________________________________________________________________________
8
MSB—ADDRESS 0Ch
SLEEP
2
7
. An undervoltage condition
ACTIVE
2
6
load until communi-
2
5
Stand-Alone Fuel-Gauge IC with
IN
in Sleep
is less than
2
4
LSb
2
3
must be issued by the master as with PMOD SLEEP. If
DQ was high when UVEN SLEEP was entered, then the
DS2788 is prepared to receive a 1-Wire reset from the
master. In the first two cases with DQ low during
SLEEP, the DS2788 does not respond to the first rising
edge of DQ with a presence pulse.
Battery voltage is measured at the V
respect to V
tion of 4.88mV. The result is updated every 440ms and
placed in the Voltage (VOLT) register in two’s comple-
ment form. Voltages above the maximum register value
are reported at the maximum value; voltages below the
minimum register value are reported at the minimum
value. Figure 3 shows the format of the Voltage register.
V
single-cell Li+ battery by a 1kΩ resistor. The input
impedance is sufficiently large (15MΩ) to be connected
to a high-impedance voltage-divider in order to support
multiple-cell applications. The pack voltage should be
divided by the number of series cells to present a sin-
gle-cell average voltage to the V
the value of R can be up to 1MΩ without incurring sig-
nificant error due to input loading. The VMA pin is dri-
ven high t
This allows an external switching element to enable the
voltage-divider, and allows settling to occur before the
start of the conversion.
IN
MSb
2
2
is usually connected to the positive terminal of a
LED Display Drivers
2
1
PRE
SS
over a range of 0 to 4.5V, with a resolu-
before the voltage conversion begins.
2
0
LSB—ADDRESS 0Dh
Voltage Measurement
X
X
IN
X
input. In Figure 2,
UNITS: 4.88mV
READ ONLY
IN
X
input with
LSb
X
7

Related parts for DS2788E+T&R