LM3824MM-2.0 National Semiconductor, LM3824MM-2.0 Datasheet - Page 8

IC CURRENT GAUGE 3% 8MSOP

LM3824MM-2.0

Manufacturer Part Number
LM3824MM-2.0
Description
IC CURRENT GAUGE 3% 8MSOP
Manufacturer
National Semiconductor
Datasheet

Specifications of LM3824MM-2.0

Function
Current Gauge
Sensing Method
High-Side
Accuracy
±3%
Voltage - Input
2 ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-MSOP, Micro8™, 8-uMAX, 8-uSOP,
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output
-
Other names
LM3824MM-2.0TR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM3824MM-2.0
Manufacturer:
NS
Quantity:
15
Part Number:
LM3824MM-2.0
Manufacturer:
NS/国半
Quantity:
20 000
www.national.com
Product Operation
The current is sampled by the delta-sigma modulator, as il-
lustrated in Figure 4 . The pulse density output of the
delta-sigma modulator is digitally filtered. The digital output
is then compared to the output of a digital ramp generator.
This produces a PWM output. The duty cycle of the PWM
output is proportional to the amount of current flowing. A duty
cycle of 50% indicates zero current flow. If the current is flow-
ing in positive direction, the duty cycle will be greater than
50%. Conversely, the duty cycle will be less than 50% for
currents flowing in the negative direction. A duty cycle of
95.5% (4.5%) indicates the current is at I
can sense currents from −I
1.0A or 2.0A. The sense current is given by:
where D is the duty cycle of the PWM waveform, and I
the full scale current (1.0A or 2.0A). Similarly, the duty cycle
is given by:
I
SENSE
= 2.2 (D−0.5)(I
MAX
to +I
MAX
FIGURE 4. Functional block diagram of LM3824
MAX
. Options for I
MAX
)
(−I
MAX
). The IC
MAX
MAX
are
is
8
For quick reference, see the Conversion Table in Table 1 .
In this IC, the current is averaged over 50 msec time slots.
Hence, momentary current surges of less than 50 msec are
tolerated.
This is a sampled data system which requires an
anti-aliasing filter, provided by the filter capacitor.
The delta-sigma modulator converts the sensed current to
the digital domain. This allows digital filtering, and provides
immunity to current and noise spikes. This type of filtering
would be difficult or impossible to accomplish on an IC with
analog components.
The user also needs to specify the full scale value. See the
Ordering Information table for details.
D = [I
SENSE
DS200007-10
/(2.2 I
MAX
)] + 0.5