ADE7763ARS Analog Devices Inc, ADE7763ARS Datasheet - Page 38
ADE7763ARS
Manufacturer Part Number
ADE7763ARS
Description
IC ENERGY METER 1PHASE 20SSOP
Manufacturer
Analog Devices Inc
Specifications of ADE7763ARS
Input Impedance
390 KOhm
Measurement Error
0.1%
Voltage - I/o High
2.4V
Voltage - I/o Low
0.8V
Current - Supply
3mA
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-SSOP (0.200", 5.30mm Width)
Meter Type
Single Phase
For Use With
EVAL-ADE7763ZEB - BOARD EVALUATION FOR ADE7763
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADE7763ARS
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADE7763ARSZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADE7763ARSZRL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADE7763
WGAI
Note that WGAIN is a signed, twos complement register
With WDIV an
expr
The calculated Wh/LSB ratio for the active energy register,
using Equation 35 is 6.378 × 10
Watt Offset
Offset calibration allows outstanding performance over a wide
dynamic range, for example, 1000:1. To do this calibration two
measurements are needed at unity power factor, one at I
the other at the lowest current to be corrected. Either calibra-
tion frequency or line cycle accumulation measurements can be
used to determine the energy offset. G
performed prior to offset calibration.
Offset calibration is performed by determining the active energy
error rate. After determining the active energy error rate, calcu-
late the value to write to the APOS register to correct the offset.
The AENERGY registers update at a rate of CLKIN/4. The twos
complement APOS register provides a fine adjustment to the
active power calculation. It represents a fixed amount of power
offset to be adjusted every CLKIN/4. The 8 LSBs of the APOS
register are fractional such that one LSB of APOS represents
1/256 of the least significant bit of the internal active energy
register. Therefore, one LSB of the APOS registe
of the AENERGY[23:0] active energy register.
See the following sections for steps to determine the active
energy error rate for both li
meter calibration options.
Calibrating Watt Offset Using a Reference Meter Examp
Figure 73 shows the step
with a reference meter.
essed as
WGAIN = INT
LAENERGY
APOS = −
INT
Wh
N is calculate
(
LSB
CF
IB
(
expected
=
d CFNUM set to 0, LAENERGY can be
AENERGY
. 3
IB(expected)
200
)
(
×
489
d to be 480 using Equation
⎛
⎜
⎝
⎛
⎜
⎝
LINECYC
imp/Wh
19186
17174
1
+
s involved in calibrating watt offset
=
) 1
CLKIN
ne accumulation and reference
Error
−
IB
−4
1
=
2 /
⎞
⎟
⎠
is
. 6
Rate
×
×
378
2
PERIOD
12
ain calibration should be
×
×
⎞
⎟
⎠
2
=
10
35
480
−
×
4
/ 8
43.
r represents 2
CLKIN
×
b
.
(
CFDEN
and
(45)
Rev. B | Page 38 of 56
−33
le
+
1
))
For this example:
Meter Constant:
Minimum Current:
Load at Minimum Current:
CF Error at Minimum Current: %ERROR
CF Numerator:
CF Denominator:
Clock Frequency:
Using Equation 45, APOS is −522 for this example.
Then,
Using Equation 45, APOS is −522.
APOS can be represented as follows with CFNUM and WDIV
set at 0:
APOS =
−
CF Absolute Error = CF
CF Absolute Error =
(%ERROR
CF Absolute Error =
AENERGY Error Rate (LSB/s) =
CF Absolute Error ×
AENERGY Error Rate (LSB/s) =
0.000110933 ×
APOS = −
⎛
⎜
⎝
(%
1
100
3 .
Figure 73. Calibrating Watt Offset Using a Reference Meter
ERROR
%
⎞
⎟
⎠
×
CF OUTPUT AND THE REFERENCE METER
CF
MEASURE THE % ERROR BETWEEN THE
9
CF(IMIN)
CALCULATE APOS. SEE EQUATION 45.
(
SET I
. 3
IMIN
6 .
. 0
OUTPUT, AND THE LOAD IN WATTS
WRITE APOS VALUE TO THE APOS
579545
×
05436
)
)
TEST
. 3
×
490
3600
) × W
REGISTER: ADDR. 0x11
1
W
200
IMIN
= I
=
×
×
CFNUM
MIN
CFDEN
=
2
×
IMIN
. 0
10
IMIN(nominal)
, V
35
MeterConst
. 0
05436
6
TEST
000110933
×
=
CLKIN
MeterConstant(imp/Wh) = 3.2
I
W
CFNUM = 0
CDEN = 489
CKIN = 3.579545 MHz
MeterConst
−
= V
MIN
+
+
522
IMIN
3600
NOM
1
1
ant
= 40 mA
− CF
, PF = 1
= 9.6 W
(imp/Wh)
Hz
IMIN(expected)
CF(IMIN)
3600
ant
(imp/Wh)
×
= 1.3%
(
CFDEN
+
) 1
×
(46)
(47)
(48)
2
35