Type
Hot-Swap Controllerr
Datasheet

Specifications of LTC1645CS8

Applications
General Purpose
Internal Switch(s)
No
Voltage - Supply
1.2 V ~ 12 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (0.154", 3.90mm Width)
Linear Misc Type
Positive Low Voltage
Family Name
LTC1645
Package Type
SOIC N
Operating Supply Voltage (min)
1.2V
Operating Supply Voltage (max)
12V
Operating Temperature (min)
0C
Operating Temperature (max)
70C
Operating Temperature Classification
Commercial
Product Depth (mm)
3.99mm
Product Height (mm)
1.5mm
Product Length (mm)
5mm
Mounting
Surface Mount
Pin Count
8
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC1645CS8
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC1645CS8#TRPBF
Manufacturer:
LT/凌特
Quantity:
20 000
PI FU CTIO S
V
from 1.2V to 12V for normal operation. I
0.2mA. An undervoltage lockout circuit disables the
LTC1645 whenever the voltage at V
SENSE2 (Pin 2/Pin 2): V
a sense resistor placed in the supply path between V
and SENSE2, the circuit breaker trips when the voltage
across the resistor exceeds 50mV for more than 1.5 s. If
the circuit breaker trip current is set to twice the normal
operating current, only 25mV is dropped across the sense
resistor during normal operation. To disable the circuit
breaker, short V
GATE2 (Pin 3/Pin 3): Channel 2 High Side Gate Drive.
Connect to the gate of an external N-channel MOSFET. An
internal charge pump guarantees at least 4.5V of gate
drive. The charge pump is powered by the higher of V
and V
on by connecting a 10 A current source from the charge
pump output to the GATE2 pin and the voltage starts to
ramp up with a slope dv/dt = 10 A/C
pin is below 2V but above 0.4V, a 40 A current source
pulls GATE2 toward ground. If the ON pin is below 0.4V,
the circuit breaker trips or the undervoltage lockout circuit
trips, the GATE2 pin is immediately pulled to ground with
a 12mA (typ) current source.
FAULT (Pin 4/NA): Circuit Breaker Fault. FAULT is an
open-drain output that pulls low when the circuit breaker
function trips. The circuit breaker is reset by pulling the ON
pin below 0.4V. An external pull-up is required to generate
a logic high at the FAULT pin. When the ON pin is low,
FAULT will release.
The circuit breaker can be programmed to automatically
reset by connecting the FAULT pin to the ON pin. In this
circuit configuration, if a logic device is driving the ON pin,
use a series resistor between the logic output and the ON
pin to prevent large currents from flowing.
RESET (Pin 5/NA): Open-Drain RESET Output. The RESET
pin is pulled low when the voltage at the FB pin goes below
1.238V or V
old. The RESET pin goes high one timing cycle after the
voltage at the FB pin goes above the FB pin threshold. The
ON pin must remain above 0.8V during this timing cycle.
CC2
U
(Pin 1/Pin 1): Positive Supply Input. V
CC2
. When the ON pin exceeds 2V, GATE2 is turned
U
CC1
is below the undervoltage lockout thresh-
CC2
U
and SENSE2 together.
CC2
(14-Lead Package/8-Lead Package)
Circuit Breaker Set Pin. With
CC2
GATE2
is less than 1.12V.
CC2
. While the ON
CC2
is typically
can range
CC2
CC1
An external pull-up is required to generate a logic high at
the RESET pin.
FB (Pin 6/NA): RESET Comparator Input. The FB pin is
used to monitor the output supply voltage with an external
resistive divider. When the voltage on the FB pin is lower
than 1.238V, the RESET pin is pulled low. A glitch filter on
the FB pin prevents fast transients from forcing RESET
low. When the voltage on the FB pin rises above the trip
point, the RESET pin goes high after one timing cycle.
GND (Pin 7/Pin 4): Ground. Connect to a ground plane for
optimum performance.
COMP
put. When the voltage on COMP
COMPOUT pulls low.
COMPOUT (Pin 9/NA): Open-Drain Spare Comparator
Output. COMPOUT pulls low when the voltage on COMP
is below 1.238V or V
threshold. An external pull-up is required to generate a
logic high at the COMPOUT pin.
ON (Pin 10/Pin 5): Analog Control Input. If the ON pin
voltage is below 0.4V, both GATE1 and GATE2 are imme-
diately pulled to ground. While the voltage is between 0.4V
and 0.8V, both GATE1 and GATE2 are each pulled to
ground with a 40 A current source. While the voltage is
between 0.8V and 2V, the GATE1 pull-up is turned on after
one timing cycle, but GATE2 continues to be pulled to
ground with a 40 A current source. When the voltage
exceeds 2V, both the GATE1 and GATE2 pull-ups are
turned on one timing cycle after the voltage exceeds 0.8V.
The ON pin is also used to reset the electronic circuit
breaker. If the ON pin is brought below and then above
0.4V following the trip of the circuit breaker, the circuit
breaker resets, and a normal power-up sequence occurs.
TIMER: (Pin 11/NA): System Timing Pin. The TIMER pin
requires an external capacitor to ground to generate a
timing delay. The pin is used to set the delay before the
RESET pin goes high after the output supply voltage is
good as sensed by the FB pin. It is also used to set the delay
between the ON pin exceeding 0.8V and the GATE1 and
GATE2 pins turning on (GATE2 turns on only if the ON pin
exceeds 2V).
+
(Pin 8/NA): Spare Comparator Noninverting In-
CC1
is below the undervoltage lockout
+
is lower than 1.238V,
LTC1645
1645fa
5
+

Related parts for LTC1645CS8