Specifications of L6226DTR

Input Type
Non-Inverting
Number Of Outputs
4
On-state Resistance
730 mOhm
Current - Output / Channel
1.4A
Current - Peak Output
2.8A
Voltage - Supply
8 V ~ 52 V
Operating Temperature
-25°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
24-SOIC (7.5mm Width)
Operating Supply Voltage
8 V to 52 V
Supply Current
10 mA
Mounting Style
SMD/SMT
For Use With
497-6816 - EVAL BOARD FOR L6226Q
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
497-3362-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
L6226DTR
Manufacturer:
SHRP
Quantity:
2 518
L6226
Figure 15. Parallel connection for higher current
To operate the device in parallel and maintain a lower over current threshold, half bridge 1
and the half bridge 2 of the bridge A can be connected in parallel and the same done for the
bridge B as shown in
still limited by the bond wires for the supply and sense pins so the dissipation in the device
will be reduced, but the peak current rating is not increased.
When connected in this configuration the over current detection circuit, senses the sum of
the current in upper devices connected in parallel. With the enables connected in parallel,
an over current will turn of both bridges.
Since the circuit senses the total current in the upper devices, the over current threshold is
equal to the threshold set the resistor R
when outputs OUT1A and OUT2A are high and resistor R
outputs OUT1B and OUT2B are high.
It is recommended to use R
In this configuration, the resulting bridge has the following characteristics.
Equivalent device: full bridge
R
1.4 A max RMS load current
2.8 A max OCD threshold
DS(ON)
0.37 Ω typ. value @ T
Figure
CLA
16. In this configuration, the peak current for each half bridge is
Doc ID 9452 Rev 4
= R
CLB
J
= 25°C
.
CLA
or R
CLB
in
Figure
CLB
16. R
sets the threshold when
CLA
Paralleled operation
sets the threshold
19/31