VNH2SP30-E STMicroelectronics, VNH2SP30-E Datasheet - Page 21

IC DRIVER MOTOR H BRIDGE

VNH2SP30-E

Manufacturer Part Number
VNH2SP30-E
Description
IC DRIVER MOTOR H BRIDGE
Manufacturer
STMicroelectronics
Type
Half Bridge Motor Driverr
Datasheet

Specifications of VNH2SP30-E

Applications
Automotive
Number Of Outputs
1
Current - Output
30A
Voltage - Supply
5.5 V ~ 16 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
30-MPSO, MultiPowerSO
Operating Supply Voltage
5.5 V to 16 V
Supply Current
10 mA
Mounting Style
SMD/SMT
Device Type
Motor
Module Configuration
Full Bridge
Peak Output Current
30A
Output Resistance
0.014ohm
Input Delay
250µs
Output Delay
250µs
Supply Voltage Range
5.5V To 36V
Rohs Compliant
Yes
No. Of Outputs
2
Output Current
30A
No. Of Pins
30
Operating Temperature Range
-40°C To +150°C
Motor Type
Half Bridge
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Load
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
497-4500-5
VNH2SP30

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
VNH2SP30-E
Manufacturer:
ST
0
Part Number:
VNH2SP30-E
Manufacturer:
ST
Quantity:
20 000
VNH2SP30-E
Note:
3.1
Figure 33. Behavior in fault condition (How a fault can be cleared)
Iout
Iout
FAULT
FAULT
(Internal Signal)
(Internal Signal)
FAULT
FAULT
(Internal Signal)
(Internal Signal)
DIAG
DIAG
EN
EN
DIAG
DIAG
EN
EN
A
A
IN
IN
IN
IN
A
A
B
B
When a fault condition is detected, the user can know which power element is in fault by
monitoring the IN
In any case, when a fault is detected, the faulty leg of the bridge is latched off. To turn on the
respective output (OUT
In case of the fault condition is not removed, the procedure for unlatching and sending the
device in Stby mode is:
- Clear the fault in the device (toggle : INA if ENA=0 or INB if ENB=0)
- Pull low all inputs, PWM and Diag/EN pins within tDEL.
If the Diag/En pins are already low, PWM=0, the fault can be cleared simply toggling the
input. The device will enter in stby mode as soon as the fault is cleared.
Reverse battery protection
Three possible solutions can be considered:
1.
2.
3.
The device sustains no more than -30A in reverse battery conditions because of the two
body diodes of the power MOSFETs. Additionally, in reverse battery condition the I/Os of
VNH2SP30-E are pulled down to the V
out
out
A
A
B
B
B
B
A
A
B
B
A
A
B
B
Operation
Operation
Normal
Normal
a Schottky diode D connected to V
an N-channel MOSFET connected to the GND pin (see
circuit for DC to 20 kHz PWM operation short circuit protection on page
a P-channel MOSFET connected to the V
OUT
OUT
Device Latched
Device Latched
to V
to V
B
B
shorted
shorted
CC
CC
A
, IN
Fault Cleared
Fault Cleared
B
, DIAG
X
) again, the input signal must rise from low to high level.
t
t
DEL
DEL
A
/EN
Stby (*)
Stby (*)
A
and DIAG
CC
CC
line (approximately -1.5V). A series resistor must
Operation
Operation
pin
Normal
Normal
CC
B
/EN
pin
OUT
OUT
B
Device Latched
Device Latched
to GND
to GND
pins.
B
B
shorted
shorted
Figure 32: Typical application
Fault Cleared
Fault Cleared
t
t
DEL
DEL
Application information
Normal
Normal
Operation
Operation
Device Unlatched
Device Unlatched
20)
21/33

Related parts for VNH2SP30-E