Specifications of IR3500VMTRPBF

Package / Case
32-MLPQ
Mounting Type
Surface Mount
Current - Supply
6.5mA
Voltage - Supply
4.75 V ~ 7.5 V
Operating Temperature
0°C ~ 100°C
Applications
Processor
Ic Function
Control IC
Supply Voltage Range
4.75V To 7.5V
Operating Temperature Range
0°C To +150°C
Digital Ic Case Style
MLPQ
No. Of Pins
32
Controller Type
XPhase
Filter Terminals
SMD
Rohs Compliant
Yes
Package
32-Lead MLPQ
Circuit
X-Phase Control IC
Switch Freq (khz)
250kHz to 1.5MHz
Pbf
PbF Option Available
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Pre-charging of converter output voltage may trigger OVP. If the converter output is pre-charged above 1.73V as
shown in Figure 17, the ROSC/OVP pin voltage will be higher than 1.6V when VCCLDRV voltage reaches 1.8V.
ROSC/OVP pin voltage will be VCCLDRV-1V and rise with VCCLDRV voltage until VCCL is above UVLO threshold,
after which ROSC/OVP pin voltage will be VCCL-1V. The converter cannot start unless the over voltage condition
stops and VCCL is cycled. If the converter output is pre-charged 130mV above VDAC but lower than 1.73V, as
shown in Figure 18, the converter will soft start until SS/DEL voltage is above 3.92V (4.0V-0.08V). Then, the over
voltage comparator is activated and fault latch is set.
During dynamic VID down, OVP could be triggered when output voltage can not follow VDAC voltage change at
light load with large output capacitance. Therefore, the over-voltage threshold is raised to 1.73V from VDAC+130mV
whenever dynamic VID is detected and the difference between output voltage and VDAC is more than 50mV, as
shown in Figure 19. The over-voltage threshold is changed back to VDAC+130mV if the difference is smaller than
50mV.
The overall system must be considered when designing for OVP. In many cases the over-current protection of the
AC-DC or DC-DC converter supplying the multiphase converter will be triggered and provide effective protection
without damage as long as all PCB traces and components are sized to handle the worst-case maximum current. If
this is not possible, a fuse can be added in the input supply to the multiphase converter.
(PHASE IC)
(PHASE IC)
OUTPUT
VOLTAGE
IIN
(ISHARE)
FAULT
LATCH
ERROR
AMPLIFIER
OUTPUT
(EAOUT)
GATEH
GATEL
(VO)
Page 20 of 34
VCCL-800 mV
VDAC
OVP
THRESHOLD
Figure 15 - Over-voltage protection during normal operation
NORMAL OPERATION
130mV
OVP CONDITION
July 28, 2008
IR3500V
AFTER
OVP