IR3080M International Rectifier, IR3080M Datasheet - Page 14

no-image

IR3080M

Manufacturer Part Number
IR3080M
Description
IC PHASE CONTROLLER 32-MLPQ
Manufacturer
International Rectifier
Series
XPhase™r
Datasheet

Specifications of IR3080M

Applications
Processor
Current - Supply
11mA
Voltage - Supply
9.5 V ~ 14 V
Operating Temperature
0°C ~ 100°C
Mounting Type
Surface Mount
Package / Case
32-MLPQ
Package
32-Lead MLPQ
Circuit
X-Phase Control IC
Switch Freq (khz)
150kHz to 1.0MHz
Pbf
PbF Option Available
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
*IR3080M

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IR3080M
Manufacturer:
IR
Quantity:
20 000
Adaptive Voltage Positioning
Adaptive voltage positioning is needed to reduce the output voltage deviations during load transients and the power
dissipation of the load when it is drawing maximum current. The circuitry related to voltage positioning is shown in
Figure 8. Resistor R
voltage. An internal current source whose value is programmed by the same external resistor that programs the
oscillator frequency pumps current into the FB pin. The error amplifier forces the converter’s output voltage lower to
maintain a balance at its inputs. R
DAC voltage.
The voltage at the VDRP pin is a buffered version of the share bus and represents the sum of the DAC voltage and
the average inductor current of all the phases. The VDRP pin is connected to the FB pin through the resistor R
Since the Error Amplifier will force the loop to maintain FB to be equal to the VDAC reference voltage, an additional
current will flow into the FB pin equal to (VDRP-VDAC) / R
positioning voltage increases accordingly. More current flows through the feedback resistor R
output voltage lower proportional to the load current. The positioning voltage can be programmed by the resistor
R
converter output impedance are referenced to and therefore independent of the VDAC voltage.
DRP
Page 14 of 41
VID4
so that the droop impedance produces the desired converter output impedance. The offset and slope of the
Note: 3. Output disabled (Fault mode)
Processor Pins (0 = low, 1 = high)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
VID3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
FB
VID2
is connected between the Error Amplifier’s inverting input pin FB and the converter’s output
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
VID1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
VID0
FB
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
is selected to program the desired amount of fixed offset voltage below the
VID5
Table 1 - Voltage Identification (VID)
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0.8375
0.8500
0.8625
0.8750
0.8875
0.9000
0.9125
0.9250
0.9375
0.9500
0.9625
0.9750
0.9875
1.0000
1.0125
1.0250
1.0375
1.0500
1.0625
1.0750
1.0875
1.1000
1.1125
1.1250
1.1375
1.1500
1.1625
1.1750
1.1875
1.2000
OFF
OFF
Vout
(V)
4
4
VID4
DRP
Processor Pins (0 = low, 1 = high)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
. When the load current increases, the adaptive
VID3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
VID2
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
VID1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
VID0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
FB
VID5
, and makes the
9
/30/04
IR3080
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1.2125
1.2250
1.2375
1.2500
1.2625
1.2750
1.2875
1.3000
1.3125
1.3250
1.3375
1.3500
1.3625
1.3750
1.3875
1.4000
1.4125
1.4250
1.4375
1.4500
1.4625
1.4750
1.4875
1.5000
1.5125
1.5250
1.5375
1.5500
1.5625
1.5750
1.5875
1.6000
Vout
(V)
DRP
.