MCP9800A0T-M/OT Microchip Technology, MCP9800A0T-M/OT Datasheet - Page 17

IC SENSOR THERMAL 2.7V SOT235

MCP9800A0T-M/OT

Manufacturer Part Number
MCP9800A0T-M/OT
Description
IC SENSOR THERMAL 2.7V SOT235
Manufacturer
Microchip Technology

Specifications of MCP9800A0T-M/OT

Package / Case
SOT-23-5, SC-74A, SOT-25
Output Type
I²C™/SMBus™
Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Alarm
No
Output Fan
Yes
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Temperature Threshold
Programmable
Full Temp Accuracy
3 C
Digital Output - Bus Interface
I2C, SMBus
Digital Output - Number Of Bits
9 bit to 12 bit
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Description/function
High Accuracy 12-bit Serial Input/Output, Thermal Monitors
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Supply Current
400 uA
Ic Output Type
Voltage
Sensing Accuracy Range
± 0.5°C
Temperature Sensing Range
-55°C To +125°C
Supply Voltage Range
2.7V To 5.5V
Resolution (bits)
12bit
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
MCP9800DM-TS1 - DEMO BOARD TEMP SENSOR MCP9800
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
MCP9800A0T-M/OTTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP9800A0T-M/OT
Manufacturer:
MICROCHIP
Quantity:
12 000
Part Number:
MCP9800A0T-M/OT
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
5.1.5
After the start condition, each bit of data in transmission
needs to be settled for time specified by t
before SCLK toggles from low-to-high (refer to the
Serial Interface Timing Specification).
5.1.6
Each receiving device, when addressed, is obliged to
generate an acknowledge bit after the reception of
each byte. The master device must generate an extra
clock pulse for ACK to be recognized.
The acknowledging device has to pull down the SDA
line for t
SCLK from the Master and remains pulled down for
t
During read, the master must signal an End-of-Data
(EOD) to the slave by not generating an ACK bit once
the last bit has been clocked out of the slave. In this
case, the slave will leave the data line released to
enable the master to generate the stop condition.
 2004 Microchip Technology Inc.
H-DATA
after high-to-low transition of SCLK.
SU-DATA
DATA VALID
ACKNOWLEDGE (ACK)
before the low-to-high transition of
SU-DATA
5.1.7
If the SCLK stays low for time specified by t
MCP9802/03 resets the serial interface. This dictates
the minimum clock speed as specified in the SMBus
specification. The I
clock speed and, therefore, the master can hold the
clock indefinitely to process data (MCP9800/01 only).
TIME OUT (MCP9802/03)
MCP9800/1/2/3
2
C bus specification does not limit
DS21909B-page 17
OUT
, the

Related parts for MCP9800A0T-M/OT