LM95235DIMM/NOPB National Semiconductor, LM95235DIMM/NOPB Datasheet - Page 14

IC TEMP SENSOR PREC REMOTE 8MSOP

LM95235DIMM/NOPB

Manufacturer Part Number
LM95235DIMM/NOPB
Description
IC TEMP SENSOR PREC REMOTE 8MSOP
Manufacturer
National Semiconductor
Series
PowerWise®, TruTherm®r
Datasheet

Specifications of LM95235DIMM/NOPB

Function
Hardware Monitor
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 85°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-MSOP, Micro8™, 8-uMAX, 8-uSOP,
Temperature Sensor Function
Temp Sensor
Interface Type
Serial (2-Wire)
Package Type
MSOP
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Ic Output Type
Digital
Sensing Accuracy Range
± 1°C
Temperature Sensing Range
-40°C To +85°C
Supply Current
350µA
Supply Voltage Range
3V To 3.6V
Resolution (bits)
13bit
Rohs Compliant
Yes
For Use With
LM95235EVAL - BOARD EVALUATION LM95235
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
LM95235DIMMTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM95235DIMM/NOPB
Manufacturer:
National Semiconductor
Quantity:
1 936
Part Number:
LM95235DIMM/NOPB
Manufacturer:
TOSHIBA
Quantity:
10 596
Part Number:
LM95235DIMM/NOPB
Manufacturer:
NS/国半
Quantity:
20 000
www.national.com
1.11 SERIAL INTERFACE RESET
In the event that the SMBus Master is RESET while the
LM95235 is transmitting on the SMBDAT line, the LM95235
must be returned to a known state in the communication pro-
tocol. This may be done in one of two ways:
1.
When SMBDAT is LOW, the LM95235 SMBus state
machine resets to the SMBus idle state if either SMBDAT
or SMBCLK are held low for more than 35 ms (t
Note that according to SMBus specification 2.0 all
devices are to timeout when either the SMBCLK or
SMBDAT lines are held low for 25 - 35 ms. Therefore, to
insure a timeout of all devices on the bus the SMBCLK
or SMBDAT lines must be held low for at least 35 ms.
TIMEOUT
).
14
2.
1.12 ONE-SHOT CONVERSION
The One-Shot register is used to initiate a single conversion
and comparison cycle when the device is in standby mode,
after which the device returns to standby. This is not a data
register and it is the write operation that causes the one-shot
conversion. The data written to this address is irrelevant and
is not stored. A zero will always be read from this register.
When SMBDAT is HIGH, have the master initiate an
SMBus start. The LM95235 will respond properly to an
SMBus start condition at any point during the
communication. After the start the LM95235 will expect
an SMBus Address address byte.

Related parts for LM95235DIMM/NOPB