Manufacturer Part Number
DS1721U+
Description
IC THERMOMETER/STAT DIG HP 8USOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1721U+

Function
Thermometer, Thermostat
Topology
ADC, Comparator, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-MSOP, Micro8™, 8-uMAX, 8-uSOP,
Full Temp Accuracy
+/- 2 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
12 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Ic Output Type
Digital
Sensing Accuracy Range
± 1°C
Supply Current
1.25mA
Supply Voltage Range
2.7V To 5.5V
Resolution (bits)
12bit
Sensor Case Style
µSOP
No. Of Pins
8
Accuracy
± 1°C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DS1721
Each additional bit of resolution approximately doubles the conversion time, so 9-bit conversions can be
performed in less than a quarter of a second.
This is accomplished by issuing a command protocol to the configuration register. It is recommended that
the user issue the command protocol to program the configuration register before any temperature
conversion commands are issued after power-up. This is due to the fact that the configuration data is
stored in volatile memory and will always power-up in the default state. The configuration register
defines the conversion mode, thermometer resolution/conversion time, and active state of the thermostat
comparator output. It also contains 3 status bits denoting the state of temperature conversions and
thermostat flags.
The user can also program over-temperature (TH) and under-temperature (TL) setpoints for thermostatic
operation. The power-up state of TH is 80°C and that for TL is 75°C. The result of each temperature
conversion is compared with these setpoints. The thermostat output (T
) becomes active when the
OUT
measured temperature exceeds the programmed TH, and remains latched in the active state until
temperature falls below TL. Thus, any hysteresis can be realized for fan control without external
components.
Digital data is written to/read from the DS1721 via a 2-wire interface, and all communication is MSb
first. Multipoint sensing is possible with the DS1721 by uniquely setting the 3-bit address of up to eight
parts on the 2-wire bus.
DS1721 FUNCTIONAL BLOCK DIAGRAM Figure 1
3 of 17