MAX6602UE9A+ Maxim Integrated Products, MAX6602UE9A+ Datasheet - Page 3

IC TEMP MONITOR 5CH 16-TSSOP

MAX6602UE9A+

Manufacturer Part Number
MAX6602UE9A+
Description
IC TEMP MONITOR 5CH 16-TSSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6602UE9A+

Function
Temp Monitoring System (Sensor)
Topology
ADC, Buffer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP
Full Temp Accuracy
+/- 1 C, +/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
11 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ELECTRICAL CHARACTERISTICS (continued)
(V
+25°C.) (Note 1)
Note 1: All parameters are tested at T
Note 2: Timing specifications are guaranteed by design.
Note 3: The serial interface resets when SCL is low for more than t
Note 4: A transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SCL’s falling edge.
SMBus INTERFACE (SCL, SDA), STBY
Logic Input Low Voltage
Logic Input High Voltage
Input Leakage Current
Output Low Voltage
Input Capacitance
SMBus-COMPATIBLE TIMING (Figures 3 and 4) (Note 2)
Serial-Clock Frequency
Bus Free Time Between STOP
and START Condition
START Condition Setup Time
Repeat START Condition Setup
Time
START Condition Hold Time
STOP Condition Setup Time
Clock Low Period
Clock High Period
Data Hold Time
Data Setup Time
Receive SCL/SDA Rise Time
Receive SCL/SDA Fall Time
Pulse Width of Spike Suppressed
SMBus Timeout
CC
= +3.0V to +5.5V, V
Five-Channel Precision Temperature Monitor
PARAMETER
_______________________________________________________________________________________
STBY
= V
CC
SYMBOL
, T
t
A
t
TIMEOUT
t
t
t
t
HD:DAT
HD:STA
SU:STO
SU:DAT
SU:STA
t
t
= +85°C. Specifications over temperature are guaranteed by design.
A
f
t
HIGH
V
C
LOW
V
V
SCL
BUF
t
t
t
SP
OL
IH
IN
R
F
IL
= -40°C to +125°C, unless otherwise noted. Typical values are at V
V
V
I
(Note 3)
f
f
f
f
90% of SCL to 90% of SDA,
f
90% of SCL to 90% of SDA,
f
10% of SDA to 90% of SCL
90% of SCL to 90% of SDA,
f
90% of SCL to 90% of SDA,
f
10% to 10%, f
10% to 10%, f
90% to 90%
f
f
f
f
f
f
SDA low period for interface reset
SINK
SCL
SCL
SCL
SCL
SCL
SCL
SCL
SCL
SCL
SCL
SCL
SCL
SCL
SCL
CC
CC
= 3.0V
= 5.0V
= 100kHz
= 400kHz
= 100kHz
= 400kHz
= 100kHz
= 400kHz
= 100kHz
= 400kHz
= 100kHz
= 400kHz (Note 4)
= 100kHz
= 400kHz
= 100kHz
= 400kHz
= 6mA
SCL
SCL
CONDITIONS
TIMEOUT
= 100kHz
= 400kHz
.
MIN
300
250
100
2.2
2.4
4.7
1.6
4.7
0.6
0.6
0.6
0.6
0.6
1.3
1.3
0.6
25
-1
4
0
TYP
37
5
CC
= +3.3V and T
MAX
400
900
300
0.8
0.3
0.3
+1
50
45
1
UNITS
kHz
ms
µA
pF
µs
µs
µs
µs
µs
µs
µs
ns
ns
µs
ns
ns
V
V
V
A
3
=

Related parts for MAX6602UE9A+