LM83CIMQAX/NOPB National Semiconductor, LM83CIMQAX/NOPB Datasheet - Page 8

IC TEMP SENSOR DIGITAL 16-SSOP

LM83CIMQAX/NOPB

Manufacturer Part Number
LM83CIMQAX/NOPB
Description
IC TEMP SENSOR DIGITAL 16-SSOP
Manufacturer
National Semiconductor
Datasheet

Specifications of LM83CIMQAX/NOPB

Function
Hardware Monitor
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
*LM83CIMQAX
*LM83CIMQAX/NOPB
LM83CIMQAX

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM83CIMQAX/NOPB
Manufacturer:
NS/TI
Quantity:
1 500
Part Number:
LM83CIMQAX/NOPB
Manufacturer:
TI/德州仪器
Quantity:
20 000
www.national.com
Logic Electrical Characteristics
Note 6: Typicals are at T
Note 7: Limits are guaranteed to National’s AOQL (Average Outgoing Quality Level).
Note 8: The Temperature Error will vary less than
Note 9: Quiescent current will not increase substantially with an active SMBus.
Note 10: This specification is provided only to indicate how often temperature data is updated. The LM83 can be read at any time without regard to conversion state
(and will yield last conversion result).
Note 11: Default values set at power up.
Note 12: Holding the SMBData and/or SMBCLK lines Low for a time interval greater than t
state of an SMBus communication (SMBCLK and SMBData set High).
1.0 Functional Description
The LM83 temperature sensor incorporates a band-gap type
temperature sensor using a Local or three Remote diodes
and an 8-bit ADC (Delta-Sigma Analog-to-Digital Converter).
The LM83 is compatible with the serial SMBus and I
wire interfaces. Digital comparators compare Local (LT) and
Remote (D1RT, D2RT and D3RT) temperature readings to
user-programmable setpoints (LHS, D1RHS, D2RHS,
D3RHS and TCS). Activation of the INT output indicates that
a comparison is greater than the limit preset in a HIGH reg-
ister. The T_CRIT setpoint (TCS) interacts with all the tem-
perature readings. Activation of the T_CRIT_A output indi-
cates that any or all of the temperature readings have
exceed the T_CRIT setpoint.
1.1 CONVERSION SEQUENCE
The LM83 converts its own temperature as well as 3 remote
diode temperatures in the following sequence:
1. Local Temperature (LT)
A
FIGURE 2. Temperature-to-Digital Transfer Function (Non-linear scale for clarity)
= 25˚C and represent most likely parametric norm.
FIGURE 3. Printed Circuit Board Used for Thermal Resistance Specifications
±
1.0 ˚C for a variation in V
2
C two
(Continued)
CC
8
DS101058-24
of 3 V to 3.6 V from the nominal of 3.3 V.
1. Remote Diode 2 (D2RT)
2. Remote Diode 1 (D1RT)
3. Remote Diode 3 (D3RT)
This round robin sequence takes approximately 480 ms to
complete as each temperature is digitized in approximately
120 ms.
1.2 INT OUTPUT and T_HIGH LIMITS
Each temperature reading (LT, D1RT, D2RT, and D3RT) is
associated with a T_HIGH setpoint register (LHS, D1RHS,
D2RHS, D3RHS). At the end of a temperature reading a digi-
tal comparison determines whether that reading has exceed
its HIGH setpoint. If the temperature reading is greater than
the HIGH setpoint, a bit is set in one of the Status Registers,
to indicate which temperature reading, and the INT output is
activated.
Local and remote temperature diodes are sampled in se-
quence by the A/D converter. The INT output and the Status
TIMEOUT
will cause the LM83 to reset SMBData and SMBCLK to the IDLE
DS101058-5

Related parts for LM83CIMQAX/NOPB