Specifications of ADT7476AARQZ-R

Function
Fan Control, Temp Monitor
Topology
ADC, Comparator, Fan Speed Counter, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
SMBus™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
24-QSOP
Full Temp Accuracy
+/- 0.5 C
Digital Output - Bus Interface
Serial (3-Wire, 4-Wire)
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Serial Bus Interface
system management bus (SMBus). The ADT7476A is
connected to this bus as a slave device, under the control of
a master controller. The ADT7476A has a 7-bit serial bus
address. When the device is powered up with Pin 13
(PWM3/ADDREN) high, the ADT7476A has a default
SMBus address of 0101110 or 0x2E. The read/write bit must
be added to get the 8-bit address. If more than one
ADT7476A is to be used in a system, each ADT7476A is
placed in ADDR SELECT mode by strapping Pin 13 low on
powerup. The logic state of Pin 14 then determines the
device’s SMBus address. The logic of these pins is sampled
on powerup.
the first valid SMBus transaction, more precisely on the
low-to-high transition at the beginning of the eighth SCL
pulse, when the serial bus address byte matches the selected
slave address. The selected slave address is chosen using the
ADDREN pin/ADDR SELECT pin. Any attempted
changes in the address have no effect after this.
Table 1. Hardwiring the ADT7476A SMBus Device
Address
Pin 13 State
Control of the ADT7476A is carried out using the serial
The device address is sampled on powerup and latched on
Figure 15. SMBus Address = 0x2C (Pin 14 = 0)
Figure 16. SMBus Address = 0x2D (Pin 14 = 1)
Figure 14. Default SMBus Address = 0x2E
0
0
1
PWM3/ADDREN
ADT7476A
ADT7476A
PWM3/ADDREN
ADT7476A
PWM3/ADDREN
Low (10 kW to GND)
High (10 kW pullup)
Don’t care
ADDR SELECT
ADDR SELECT
ADDR SELECT
Pin 14 State
14
13
ADDRESS = 0x2D
14
13
ADDRESS = 0x2E
14
13
ADDRESS = 0x2C
V
10k
V
CC
CC
10k
10kW
W
W
0101100 (0x2C)
0101101 (0x2D)
0101110 (0x2E)
Address
http://onsemi.com
10
slave address allows the user to avoid conflicts with other
devices sharing the same serial bus, for example, if more
than one ADT7476A is used in a system.
The serial bus protocol operates as follows:
The ability to make hardwired changes to the SMBus
Figure 17. Unpredictable SMBus Address if Pin 13
1. The master initiates data transfer by establishing a
2. Data is sent over the serial bus in sequences of
3. When all data bytes have been read or written,
CARE SHOULD BE TAKEN TO ENSURE THAT PIN 13
(PWM3/ADDREN) IS EITHER TIED HIGH OR LOW. LEAVING PIN 13
FLOATING COULD CAUSE THE ADT7476A TO POWER UP WITH AN
UNEXPECTED ADDRESS.
NOTE THAT IF THE ADT7476A IS PLACED INTO ADDR SELECT
MODE, PINS 13 AND 14 CANNOT BE USED AS THE ALTERNATIVE
FUNCTIONS (PWM3, TACH4/THERM) UNLESS THE CORRECT
CIRCUIT IS MUXED IN AT THE CORRECT TIME OR DESIGNED TO
HANDLE THESE DUAL FUNCTIONS.
start condition, which is defined as a high-to-low
transition on the serial data line SDA while the
serial clock line SCL remains high. This indicates
that an address/data stream follows. All slave
peripherals connected to the serial bus respond to
the start condition and shift in the next eight bits,
consisting of a 7-bit address (MSB first), plus a
R/W bit, which determine the direction of the data
transfer, that is, whether data is written to or read
from the slave device.
The peripheral whose address corresponds to the
transmitted address responds by pulling the data
line low during the low period before the ninth
clock pulse, known as the acknowledge bit. All
other devices on the bus now remain idle while the
selected device waits for data to be read from or
written to it. If the R/W bit is a 0, the master writes
to the slave device. If the R/W bit is a 1, the
master reads from the slave device.
nine clock pulses, eight bits of data followed by an
acknowledge bit from the slave device. Transitions
on the data line must occur during the low period
of the clock signal and remain stable during the
high period. A low-to-high transition, when the
clock is high, can be interpreted as a stop signal.
The number of data bytes transmitted over the
serial bus in a single read or write operation is
limited only by what the master and slave devices
can handle.
stop conditions are established. In write mode, the
master pulls the data line high during the 10
ADT7476A
PWM3/ADDREN
ADDR SELECT
is Unconnected
14
13
DO NOT LEAVE ADDREN
UNCONNECTED! CAN
CAUSE UNPREDICTABLE
ADDRESSES.