ADT7481ARMZ-001 ON Semiconductor, ADT7481ARMZ-001 Datasheet - Page 15

no-image

ADT7481ARMZ-001

Manufacturer Part Number
ADT7481ARMZ-001
Description
IC SENSOR TEMP 2CH ALARM 10MSOP
Manufacturer
ON Semiconductor
Datasheet

Specifications of ADT7481ARMZ-001

Function
Temp Monitoring System (Sensor)
Topology
ADC, Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 120°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 120°C
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Temperature Sensor Function
Temp Sensor
Interface Type
Serial (2-Wire)
Package Type
MSOP
Operating Temperature (min)
0C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Full Temp Accuracy
+/- 2.5 C
Digital Output - Bus Interface
Serial (2-Wire)
Maximum Operating Temperature
+ 127 C
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7481ARMZ-001
Manufacturer:
ADI/亚德诺
Quantity:
20 000
scenarios:
NOTES: It is possible to read a data byte from a data register
without first writing to the address pointer register.
However, if the address pointer register is already at the
correct value, it is not possible to write data to a register
without writing to the address pointer register. This is
because the first data byte of a write is always written to the
address pointer register.
Remember that some of the ADT7481 registers have
different addresses for read and write operations. The write
address of a register must be written to the address pointer
if data is to be written to that register, but it may not be
possible to read data from that address. The read address of
a register must be written to the address pointer before data
can be read from that register.
ALERT Output
output goes low whenever an out−of−limit measurement is
detected, or if the remote temperature sensor is open circuit.
It is an open−drain output and requires a pullup. Several
ALERT outputs can be wire−OR’ed together, so that the
common line will go low if one or more of the ALERT
outputs goes low.
processor, or it may be used as an SMBALERT. Slave
devices on the SMBus cannot normally signal to the bus
master that they want to talk, but the SMBALERT function
allows them to do so.
common SMBALERT line connected to the master. When
When reading data from a register there are two possible
Pin 8 can be configured as an ALERT output. The ALERT
The ALERT output can be used as an interrupt signal to a
One or more ALERT outputs can be connected to a
If the address pointer register value of the ADT7481 is
unknown or not the desired value, it is necessary to set it
to the correct value before data can be read from the
desired data register. This is done by performing a write
to the ADT7481 as before, but only the data byte
containing the register read address is sent, as data is not
to be written to the register. This is shown in Figure 16.
If the address pointer register is already at the desired
address, data can be read from the corresponding data
register without first writing to the address pointer
register, and the bus transaction shown in Figure 16 can
be omitted.
A read operation is then performed consisting of the
serial bus address, R/W bit set to 1, followed by the data
byte read from the data register (shown in Figure 17).
http://onsemi.com
15
the SMBALERT line is pulled low by one of the devices, the
following procedure occurs as illustrated in Figure 18.
Masking the ALERT Output
Remote 2 or all three channels. This is done by setting the
appropriate mask bits in either the Configuration 1 register
(read address = 0x03, write address = 0x09) or in the
consecutive ALERT register (address = 0x22)
To mask ALERTs due to local temperature, set Bit 5 of the
consecutive ALERT register to 1. Default = 0.
To mask ALERTs due to Remote 1 temperature, set Bit 1 of
the Configuration 1 register to 1. Default = 0.
To mask ALERTs due to Remote 2 temperature, set Bit 0 of
the Configuration 1 register to 1. Default = 0.
To mask ALERTs due to any channel, set Bit 7 of the
Configuration 1 register to 1. Default = 0.
The ALERT output can be masked for local, Remote 1,
START
MASTER
RECEIVES
SMBALERT
1. SMBALERT is pulled low.
2. Master initiates a read operation and sends the
3. The device with a low ALERT output responds to
4. If more than one device has a low ALERT output,
5. Once the ADT7481 has responded to the alert
alert response address (ARA = 0001 100). This is
a general call address that must not be used as a
specific device address.
the alert response address, and the master reads the
address from the responding device. An LSB of 1
is added because the device address is comprised
of seven bits. The address of the device is now
known and it can be interrogated in the usual way.
the one with the lowest device address will have
priority, in accordance with normal SMBus
arbitration.
response address, it will reset its ALERT output,
provided that the error condition that caused the
ALERT no longer exists. If the SMBALERT line
remains low, the master sends the ARA again, and
so on until all devices with low ALERT outputs
respond.
ALERT RESPONSE
MASTER SENDS
ARA AND READ
Figure 18. Use of SMBALERT
ADDRESS
COMMAND
RD
ACK
DEVICE SENDS
ITS ADDRESS
ADDRESS
DEVICE
ACK
NO
STOP

Related parts for ADT7481ARMZ-001