FM75M8 Fairchild Semiconductor, FM75M8 Datasheet - Page 9

no-image

FM75M8

Manufacturer Part Number
FM75M8
Description
TEMPERATURE SENSOR LV 8SOIC
Manufacturer
Fairchild Semiconductor
Datasheet

Specifications of FM75M8

Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
Internal
Sensing Temperature
-40°C ~ 125°C
Output Type
SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Full Temp Accuracy
4 C
Digital Output - Bus Interface
I2C, SMBus
Digital Output - Number Of Bits
9 bit to 12 bit
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Description/function
Semiconductor
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Supply Current
500 uA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FM75M8X
Manufacturer:
FSC
Quantity:
8 325
Part Number:
FM75M8X
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Company:
Part Number:
FM75M8X
Quantity:
21
© 2006 Fairchild Semiconductor Corporation
FM75 Rev. 1.0.8
Temperature Register
The temperature register is a two-byte (16-bit) read-only
register. Digital temperatures from the T-to-D converter
are stored in the temperature register in two’s comple-
ment format and the contents of this register are updated
at regular intervals, each time the T-to-D conversion is
finished.
The user can read data from the temperature register at
any time. When a T-to-D conversion is completed, the
new data is loaded into a comparator buffer to evaluate
fault conditions and updates the temperature register if a
read cycle is not ongoing. The FM75 is continuously
evaluating fault conditions regardless of read or write
activity on the bus. If a read is ongoing, the previous
temperature is read. The readable temperature is
updated upon the completion of the next T-to-D conver-
sion not masked by a read cycle.
The temperature register is illustrated in Figure 7.
Depending on the resolution of the T-to-D conversion,
the 9, 10, 11, or 12 MSBs of the register contain temper-
ature data. All unused bits following the digital tempera-
ture are zero. The MSB position of the temperature
register always contains the sign bit for the digital tem-
perature and bit 14 contains the temperature MSB. Bits
in the temperature register default to zero at power-up.
SB = Two’s complement sign bit
TMSB = Temperature MSB
T = Temperature data
9-bit LSB = Temperature LSB for 9-bit conversions
10-bit LSB = Temperature LSB for 10-bit conversions
11-bit LSB = Temperature LSB for 11-bit conversions
12-bit LSB = Temperature LSB for 12-bit conversions
MSB
SB
Figure 7. Temperature Register Format
9-bit
LSB
TMSB
7
14
10-bit
LSB
6
13
T
11-bit
LSB
5
12
T
12-bit
LSB
4
11
T
0
3
10
T
0
2
T
9
0
1
T
8
LSB
0
9
Configuration Register
The configuration register is a one-byte (8-bit) read/write
register (see Figure 8). This register allows the user to
control the FM75 shutdown mode as well as the follow-
ing thermal alarm features: polarity, operating mode, and
fault tolerance. The configuration register contains two
bits that set the fault tolerance trip point. The fault toler-
ance trip point is the number of consecutive times the
internal circuit reads the temperature and finds the tem-
perature outside the limits programmed. The pro-
grammed limits are defined by the T
upper limit and by the T
Table 4 shows the relationship between F1 and F0 and
the number of consecutive errors or “trips” needed to
activate the alarm. The configuration register also con-
tains the two bits that set the T-to-D conversion resolu-
tion to 9, 10, 11, or 12 bits. Table 3 shows the
relationship between R1 and T0 and the conversion res-
olution. All bits in the configuration register default to
zero at power-up.
Table 3. Conversion Resolution Settings
Table 4. Fault Tolerance Settings
R1 = Resolution bit 1 (see Table 3).
R0 = Resolution bit 0 (see Table 3).
F1 = Fault tolerance bit 1 (see Table 4).
F0 = Fault tolerance bit 0 (see Table 4).
POL = OS output polarity: 0 = active low, 1 = active
high.
CMP/INT = thermostat mode: 0 = comparator mode,
1 = inerrupt mode.
SD = shutdown: 0 = normal operation, 1 = shutdown
mode.
MSB
Conversion Resolution
X R1 R0 F1 F0
Figure 8. Configuration Register Format
Fault Tolerance
6
A-to-D
10 Bits
11 Bits
12 Bits
9 Bits
1
2
4
6
5
4
HYST
register for the lower limit.
3
POL
2
OS
R1
R1
CMP/
0
0
1
1
0
0
1
1
INT
register for the
1
www.fairchildsemi.com
LSB
SD
R0
R0
0
1
0
1
0
1
0
1