LM84CIMQA National Semiconductor, LM84CIMQA Datasheet - Page 6

IC TEMP SENSOR DIGITAL 16-SSOP

LM84CIMQA

Manufacturer Part Number
LM84CIMQA
Description
IC TEMP SENSOR DIGITAL 16-SSOP
Manufacturer
National Semiconductor
Datasheet

Specifications of LM84CIMQA

Function
Hardware Monitor
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 125°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
0°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-SSOP
For Use With
LM84EVAL - EVALUATION BOARD FOR LM84
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
*LM84CIMQA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM84CIMQA
Manufacturer:
NS
Quantity:
2
Part Number:
LM84CIMQA
Manufacturer:
SMD
Quantity:
1
Part Number:
LM84CIMQA
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM84CIMQAX
Manufacturer:
NEC
Quantity:
56
www.national.com
f
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
Symbol
SMB
LOW
LOW
HIGH
R;SMB
F;SMB
OF
TIMEOUT
1
2
SU;DAT
3
HD;DAT
4
HD;STA
5
SU;STO
6
SU;STA
BUF
Logic Electrical Characteristics
SMBus DIGITAL SWITCHING CHARACTERISTICS
Unless otherwise noted, these specifications apply for V
pF. Boldface limits apply for T
The switching characteristics of the LM84 fully meet or exceed the published specifications of the SMBus or I
lowing parameters are the timing relationships between SMBCLK and SMBData signals related to the LM84. They are not nec-
essarily the I
,
,
,
,
,
SEXT Cumulative Clock Low Extend Time
SMBus Clock Frequency
SMBus Clock Low Time
SMBus Clock High Time
SMBus Rise Time
SMBus Fall Time
Output Fall Time
SMBData and SMBCLK Time Low for
Reset of Serial Interface (Note 13)
SMBCLK (Clock) Period
Data In Setup Time to SMBCLK High
Data Out Stable after SMBCLK Low
SMBData Low Setup Time to SMBCLK
Low
SMBData High Delay Time after
SMBCLK High (Stop Condition Setup)
SMBus Start-Condition Setup Time
SMBus Free Time
2
C or SMBus bus specifications.
Parameter
A
= T
J
= T
MIN
to T
SMBus Communication
MAX
(Continued)
; all other limits T
CC
10% to 10%
90% to 90%
10% to 90%
90% to 10%
C
I
O
=+3.0 Vdc to +3.6 Vdc, C
L
= 3 mA
= 400 pF
6
Conditions
A
= T
J
= +25˚C, unless otherwise noted.
L
(load capacitance) on output lines = 80
(Note 6)
Typical
0.3
1
(Note 7)
Limits
400
250
100
100
100
1.3
0.6
2.5
0.9
0.6
1.3
10
25
25
25
40
0
2
C bus. The fol-
DS100961-4
kHz (max)
kHz (min)
ms (max)
ms (max)
ms (max)
ns (max)
ms (min)
µs (max)
µs (min)
µs (min)
µs (min)
ns (min)
ns (min)
ns (min)
ns (min)
µs (min)
µs (min)
(Limit)
Units
µs
µs

Related parts for LM84CIMQA