AD680ANZ Analog Devices Inc, AD680ANZ Datasheet - Page 4

no-image

AD680ANZ

Manufacturer Part Number
AD680ANZ
Description
IC VREF PREC 2.5V LP 8-DIP
Manufacturer
Analog Devices Inc
Type
Voltage Referencer
Datasheets

Specifications of AD680ANZ

Temperature Coefficient
20ppm/°C
Reference Type
Series
Voltage - Output
2.5V
Tolerance
±0.2%
Voltage - Input
4.5 ~ 36 V
Number Of Channels
1
Current - Quiescent
250µA
Current - Output
50mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
Topology
Series
Input Voltage
4.5V To 36V
Reference Voltage
2.5V
Reference Voltage Tolerance
5mV
Voltage Reference Case Style
DIP
No. Of Pins
8
Current, Output
0 to 10 mA
Current, Supply
195 μA
Package Type
PDIP-8
Power Dissipation
1 mW
Regulation, Line
40 μV/V
Regulation, Load
80 μV/mA
Regulator Type
Switching
Temperature, Operating, Range
-40 to +85 °C
Voltage, Input
5 V
Voltage, Noise
8 μVp-p
Voltage, Output
2.5 V
Voltage, Supply
4.5 to 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Cathode
-
Lead Free Status / Rohs Status
RoHS Compliant part Electrostatic Device
AD680
ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter
V
Power Dissipation (25°C)
Storage Temperature
Lead Temperature (Soldering, 10 sec)
Package Thermal Resistance θ
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
IN
to Ground
JA
(All Packages)
Rating
36 V
500 mW
−65°C to +125°C
300°C
120°C/W
Rev. H | Page 4 of 12
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
OUTPUT PROTECTION
Output safe for indefinite short to GND and momentary short
to −V
IN
.