LT6656ACS6-2.5#TRPBF Linear Technology, LT6656ACS6-2.5#TRPBF Datasheet - Page 5

IC SERIES VOLT REF 2.5V TSOT23-6

LT6656ACS6-2.5#TRPBF

Manufacturer Part Number
LT6656ACS6-2.5#TRPBF
Description
IC SERIES VOLT REF 2.5V TSOT23-6
Manufacturer
Linear Technology
Datasheet

Specifications of LT6656ACS6-2.5#TRPBF

Reference Type
Series
Voltage - Output
2.5V
Tolerance
±0.05%
Temperature Coefficient
10ppm/°C
Voltage - Input
3 ~ 18 V
Number Of Channels
1
Current - Quiescent
850nA
Current - Output
5mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
TSOT-23-6, TSOT-6
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Cathode
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LT6656ACS6-2.5#TRPBFLT6656ACS6-2.5
Manufacturer:
LT
Quantity:
10 000
Company:
Part Number:
LT6656ACS6-2.5#TRPBFLT6656ACS6-2.5#PBF
Manufacturer:
LT
Quantity:
3 000
Company:
Part Number:
LT6656ACS6-2.5#TRPBFLT6656ACS6-2.5#PBF/AI/BC/BI
Manufacturer:
LT
Quantity:
71
Company:
Part Number:
LT6656ACS6-2.5#TRPBF
Manufacturer:
LT
Quantity:
11 903
elecTrical characTerisTics
Typical perForMance characTerisTics
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: If the parts are stored outside of the specified temperature range,
the output may shift due to hysteresis.
Note 3: The stated temperature is typical for soldering of the leads during
manual rework. For detailed IR reflow recommendations, refer to the
Applications section.
Note 4: Temperature coefficient is measured by dividing the maximum
change in output voltage by the specified temperature range.
Note 5: Load regulation is measured with a pulse from no load to the
specified load current. Output changes due to die temperature change
must be taken into account separately.
Note 6: Excludes load regulation errors.
Note 7: Peak-to-peak noise is measured with a 3-pole highpass filter at
0.1Hz and a 4-pole lowpass filter at 10Hz. The unit is enclosed in a still-air
10000
–1000
9000
8000
7000
6000
5000
4000
3000
2000
1000
0
–60 –40
Output Voltage Temperature Drift
ALL OPTIONS
25 TYPICAL UNITS
NORMALIZED AT 25°C
C
I
L
L
= 0
= 1µF
–20 0
TEMPERATURE (°C)
20 40
60
80
100
6652 G01
120
200
180
160
140
120
100
80
60
40
20
–0.10
0
Typical V
ALL OPTIONS
C
I
T
L
A
L
= 0
= 25°C
= 1µF
–0.06
OUTPUT VOLTAGE ERROR (%)
OUT
–0.02
Distribution
environment to eliminate thermocouple effects on the leads. The test
time is 10 seconds. RMS noise is measured on a spectrum analyzer in a
shielded environment.
Note 8: Long term stability typically has a logarithmic characteristic and
therefore, changes after 1000 hours tend to be much smaller than before
that time. Total drift in the second thousand hours is normally less than
one third that of the first thousand hours with a continuing trend toward
reduced drift with time. Long-term stability will also be affected by
differential stresses between the IC and the board material created during
board assembly.
Note 9: Hysteresis in output voltage is created by mechanical stress
that differs depending on whether the IC was previously at a higher or
lower temperature. Output voltage is always measured at 25°C, but
the IC is cycled to the hot or cold temperature limit before successive
measurements. For instruments that are stored at well controlled
temperatures (within 20 or 30 degrees of operational temperature)
hysteresis is usually not a dominant error source.
0
0.02
0.06
6656 G02
0.10
100
0.1
10
1
0
Supply Current vs Input Voltage
1.25V OPTION
2
4
6
INPUT VOLTAGE (V)
8
10
12
LT6656
14
T
T
T
T
T
A
A
A
A
A
16
= 125°C
= 85°C
= 25°C
= –40°C
= –55°C
18
6656 G17
6656fa

20

Related parts for LT6656ACS6-2.5#TRPBF