S-8335A160FT-TB-G Seiko Instruments, S-8335A160FT-TB-G Datasheet - Page 21

no-image

S-8335A160FT-TB-G

Manufacturer Part Number
S-8335A160FT-TB-G
Description
IC REG SW 3CH STEP UP 24-TSSOP
Manufacturer
Seiko Instruments
Type
Step-Up (Boost), Invertingr
Datasheet

Specifications of S-8335A160FT-TB-G

Internal Switch(s)
Yes
Synchronous Rectifier
No
Number Of Outputs
1
Voltage - Output
7.48 ~ 13.93 V, -5.44 ~ -10.13 V
Frequency - Switching
100kHz
Voltage - Input
2.4 ~ 5 V
Operating Temperature
-20°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
24-TSSOP
Power - Output
650mW
Output Voltage
13.93 V
Operating Temperature Range
- 20 C to + 70 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Rev.6.0
Electric volume
VDIN:
VCLK:
VSTR_B: This is the strobe signal input pin.
_01
VSTR_B
This is the data input pin to the electric volume.
"Data 1" is an input for the “H” level, and "data 0" is an input for the "L" level.
(A high impedance state is prohibited.) When no data is sent, keep VDIN at the "L" level.
This is the clock input pin to the electric
volume.
The data of the VDIN pin is fetched to the
shift register at the clock rising edge.
When a clock with more than six bits data
is input, the data that had been read is
sequentially shifted at each clock pulse,
and the last six bits of data become
effective.
When the strobe signal goes low (set to "L"
level), the shift register contents are
fetched to the latch.
fetched to the latch is sent directly to the
electric volume, and consequently the
output voltage changes. When the strobe
signal goes high (set to "H" level), the latch
data is held.
STEP-UP, FOR LCD BIAS SUPPLY, 3-CHANNEL SWITCHING REGULATOR
VDIN
VCLK
Figure 9 Block Diagram and Clock Timing of Electric Volume Part
RESET
6-bit latch
6-bit shift
register
The data that is
Electric
volume
Seiko Instruments Inc.
VSTR_B
VOUT
VOUT
VCLK
VDIN
Reset
±1/2
LSB
min. value
Output
voltage
(V)
Hold
0
(MSB)
D5
1
Figure 10 Linearity Error
D4
D3
31
D2
32
D1
(LSB)
D0
S-8335 Series
Read
62 63
Setting
value
Hold
±1/2 LSB
Electric
volume
data
(DEC)
21