LICAL-ENC-MS001 Linx Technologies Inc, LICAL-ENC-MS001 Datasheet - Page 5

IC ENCODER MS SERIES 20-SSOP

LICAL-ENC-MS001

Manufacturer Part Number
LICAL-ENC-MS001
Description
IC ENCODER MS SERIES 20-SSOP
Manufacturer
Linx Technologies Inc
Series
MSr
Type
Encoderr
Datasheet

Specifications of LICAL-ENC-MS001

Package / Case
20-SSOP
Applications
RF, IR
Mounting Type
Surface Mount
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LICAL-ENC-MS001
Manufacturer:
LINX
Quantity:
320
Part Number:
LICAL-ENC-MS001
Manufacturer:
LinxTechnologies
Quantity:
838
ENCODER OPERATION
CREATE MODE
SEND MODE
Page 8
Upon power up, the encoder will set the baud rate based on the state of the
SEL_BAUD lines and then check the SEND line. If it is high, the encoder will go
directly to Send Mode. Otherwise, it will pull the TX_CTNL line low and go into
low-power sleep mode. It will remain asleep until either the CREATE_ADDR or
SEND line goes high. These lines will place the encoder in either Create Mode
or Send Mode as described in the following sections.
The Create Mode allows the generation of a unique address to ensure the
security of transmission and prevent unintentional operation of devices. The MS
encoder allows 16,777,216 (2
remarkably straightforward.
When the CREATE_ADDR line is pulled high, the encoder randomizes the Code
Word continuously until the CREATE_ADDR line is pulled low. Once the encoder
registers the low line, the Code Word is saved and the encoder will begin to
toggle the MODE_IND line. This will indicate to the user that the encoder is ready
to accept the Control Permissions. Control Permissions are set by activating the
data lines that the user wants the encoder to have the authority to operate.
Pulling the CREATE_ADDR line high again will cause the encoder to save the
Control Permissions and go back to sleep. The Code Word will be sent with
every transmission when the SEND line is pulled high, but the encoder can only
activate the decoder data lines that are authorized by the Control Permissions.
The Code Word is learned by an MS Series decoder by placing the decoder into
Learn Mode and sending a transmission from the encoder. Please refer to the
MS Series Decoder Data Guide for full details.
The CREATE_ADDR line can be tied to a button or contact point accessible by
the user. With a simple press, the user will generate a unique address that
should never again require changing. Some designers may prefer to set a code
during production and not provide for change by the user.
The MODE_IND line allows for the connection of a LED or other device to
indicate to the user that the encoder is in Create Mode. Once the
CREATE_ADDR line goes high and the encoder enters Create Mode, the
MODE_IND line will go high and stay high until the CREATE_ADDR line goes
low. The MODE_IND line is capable of sourcing up to 25mA of current.
When the SEND line goes high the encoder will enter Send Mode. The encoder will
pull the TX_CNTL line high to activate the transmitter, record the state of the data
lines, assemble the packet, and send it through the DATA_OUT line. It will continue
doing this for as long as the SEND line is high, updating the state of the data lines
with each transmission. Once SEND is pulled low the encoder will finish the current
transmission, pull TX_CNTL low to deactivate the transmitter, and go to sleep.
For simple applications that require only a single input, SEND can be tied directly
to the data input line, allowing a single connection. If additional lines are used in
this manner, diodes or dual contact switches will be necessary to prevent voltage
on one data line from activating all of the data lines. The Application Example
section demonstrates the use of diodes for this purpose.
24
) possible addresses. Creating the address is
Figure 6: MS Series Encoder Flowchart
Pull MODE_IND
Save Control
Permissions
Line Low
YES
YES
YES
Pull The TX_CNTL
SEND Line High?
CREATE_ADDR
Randomize Code
CREATE_ADDR
Save Code Word
CREATE_ADDR
Poll Data Lines &
Pull MODE_IND
Pull MODE_IND
Update Control
Set Baud Rate
Start Toggling
Permissions
MODE_IND
Line High?
Line High?
Line High?
Power Up
Time Out?
Line High
Line Low
Line Low
Is the
Is the
Word
Is the
Is the
NO
NO
YES
NO
NO
YES
NO
Sleep
SEND Line High?
Is the
NO
YES
Pull The TX_CNTL
Get the Data From
the Data Lines
Compare With
Send the Data
Permissions
Line High
Control
Packet
Page 9