IDT72P51749L6BB IDT, Integrated Device Technology Inc, IDT72P51749L6BB Datasheet - Page 27

IC FLOW CTRL 36BIT 256-BGA

IDT72P51749L6BB

Manufacturer Part Number
IDT72P51749L6BB
Description
IC FLOW CTRL 36BIT 256-BGA
Manufacturer
IDT, Integrated Device Technology Inc
Datasheets

Specifications of IDT72P51749L6BB

Configuration
Dual
Density
1.125Mb
Access Time (max)
3.7ns
Word Size
36b
Sync/async
Synchronous
Expandable
Yes
Bus Direction
Uni-Directional
Package Type
BGA
Clock Freq (max)
166MHz
Supply Current
150mA
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
256
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
72P51749L6BB

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT72P51749L6BB
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT72P51749L6BB8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT72P51749L6BBI
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT72P51749L6BBI8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
TABLE 5 — READ ADDRESS BUS, RDADD[7:0]
READ QUEUE SELECTION AND READ OPERATION
(STANDARD MODE)
can be configured up to a maximum of 128 queues which data can be read via
a common read port using the data outputs (Qout), read clock (RCLK) and read
enable (REN). An output enable, OE control pin is also provided to allow High-
Impedance selection of the Qout data outputs. The multi-queue device read port
operates in standard IDT mode and “First Word Fall Through” mode (see
Figure 46, Write Operations in First Word Fall Through). The queue to be read
is selected by the address presented on the read address bus (RDADD) during
a rising edge on RCLK while read address enable (RADEN) is HIGH. The state
of REN does not impact the queue selection. The queue selection requires 1
RCLK cycles. All subsequent data reads will be from this queue until another
queue is selected.
IDT72P51749/72P51759/72P51769 1.8V, MULTI-QUEUE FLOW-CONTROL DEVICES
(128 QUEUES) 36 BIT WIDE CONFIGURATION 1,179,648, 2,359,296, and 4,718,592
bits
The IDT72P51749/72P51759/72P51769 multi-queue flow-control devices
Read Queue
PAEn/PRn
Quadrant
Operation RCLK
Select
Select
RADEN
1
0
Status Word
Address
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
27
ESTR
device. The read port is designed such that 100% bus utilization can be
obtained. This means that data can be read out of the device on every RCLK
rising edge including the cycle that a new queue is being addressed.
(see Figure 48, Read Queue Select, Read Operation). RADEN goes high
signaling a change of queue (clock cycle “D”). The address on RDADD at that
time determines the next queue. Data presented during that cycle (“D”) will be
read at “D” (+ t
(old) queue (Q
these two clock cycles, data will not be read from the previous queue. The next
cycle’s rising edge (“F”), the read port discrete empty flag will update to show
the empty status of the newly selected queue (Q
loaded at this time (“F”) with the last word from the previous (old) queue (Q
0
1
Standard mode operation is defined as individual words will be read from the
Changing queues requires a minimum of four RCLK cycles on the read port
Queue Status on PAEn/PRn Bus
Q0 : Q7 → PAF0 : PAF7
Q8 : Q15 → PAF0 : PAF7
Q16 : Q23 → PAF0 : PAF7
Q24 : Q31 → PAF0 : PAF7
Q32 : Q39 → PAF0 : PAF7
Q40 : Q47 → PAF0 : PAF7
Q48 : Q55 → PAF0 : PAF7
Q56 : Q63 → PAF0 : PAF7
Q64 : Q71 → PAF0 : PAF7
Q72 : Q79 → PAF0 : PAF7
Q80 : Q87 → PAF0 : PAF7
Q88 : Q95 → PAF0 : PAF7
Q96 : Q103 → PAF0 : PAF7
Q104 : Q111 → PAF0 : PAF7
Q112 : Q119 → PAF0 : PAF7
Q120 : Q127 → PAF0 : PAF7
Device Select
(Compared to
ID0,1,2)
Device Select
(Compared to
ID0,1,2)
7 6 5
7 6 5
A
), and the next cycle (“E”), can continue to be read from the active
P
), provided REN is active LOW. If REN is HIGH (inactive) for
RDADD[7:0]
Read Queue Address
(6 bits = 64 Queues
7 bits = 128 Queues)
X
4 3 2
4
3 2 1 0
Status Word
COMMERCIAL AND INDUSTRIAL
Address
1 0
6714 drw12
TEMPERATURE RANGES
F
). The internal pipeline is also
SEPTEMBER 27, 2004
F
)

Related parts for IDT72P51749L6BB