ADUM2201ARWZ Analog Devices Inc, ADUM2201ARWZ Datasheet - Page 11

no-image

ADUM2201ARWZ

Manufacturer Part Number
ADUM2201ARWZ
Description
IC ISOLATOR DIGITAL DUAL 16SOIC
Manufacturer
Analog Devices Inc
Series
iCoupler®r
Datasheet

Specifications of ADUM2201ARWZ

Propagation Delay
150ns
Inputs - Side 1/side 2
1/1
Number Of Channels
2
Isolation Rating
5000Vrms
Voltage - Supply
3 V ~ 5.5 V
Data Rate
1Mbps
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
No. Of Channels
2
Supply Current
1.1mA
Supply Voltage Range
3V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
-40°C To +105°C
Package
16SOIC W
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM2201ARWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADUM2201ARWZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADUM2201ARWZ-RL
Quantity:
1 000
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
means of protective circuits. Note that the asterisk (*) branded on packages denotes DIN V VDE V 0884-10 approval for 846 V peak
working voltage.
Table 7.
Description
Installation Classification per DIN VDE 0110
Climatic Classification
Pollution Degree (DIN VDE 0110, Table 1)
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
Input-to-Output Test Voltage, Method A
Highest Allowable Overvoltage
Safety-Limiting Values
Insulation Resistance at T
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 450 V rms
For Rated Mains Voltage ≤ 600 V rms
After Environmental Tests Subgroup 1
After Input and/or Safety Test Subgroup 2
and Subgroup 3
Case Temperature
Side 1 Current
Side 2 Current
Figure 3. Thermal Derating Curve, Dependence of Safety Limiting
350
300
250
200
150
100
50
0
Values with Case Temperature per DIN V VDE V 0884-10
0
50
SIDE 1
CASE TEMPERATURE (°C)
S
SIDE 2
100
150
Conditions
V
partial discharge < 5 pC
V
V
Transient overvoltage, t
Maximum value allowed in the event of a failure;
see Figure 3
V
IORM
IORM
IORM
IO
= 500 V
× 1.875 = V
× 1.6 = V
× 1.2 = V
200
Rev. A | Page 11 of 20
PR
PR
, t
, t
PR
m
m
, 100% production test, t
= 60 sec, partial discharge < 5 pC
= 60 sec, partial discharge < 5 pC
TR
= 10 seconds
RECOMMENDED OPERATING CONDITIONS
Table 8.
Parameter
Operating Temperature
Supply Voltages
Input Signal Rise and Fall Times
1
and Magnetic Field Immunity
external magnetic fields.
All voltages are relative to their respective ground. See the
m
1
= 1 sec,
section for information on immunity to
ADuM2200/ADuM2201
Symbol
V
V
V
V
T
I
I
R
S1
S2
S
IORM
PR
PR
TR
S
Symbol
T
V
A
DD1
, V
Characteristic
I to IV
I to II
I to II
40/105/21
2
846
1590
6000
150
265
335
>10
1375
1018
DD2
9
Min
−40
3.0
DC Correctness
Max
+105 °C
5.5
1.0
Unit
V peak
V peak
V peak
V peak
V peak
°C
mA
mA
Ω
Unit
V
ms