AD261BND-4 Analog Devices Inc, AD261BND-4 Datasheet
AD261BND-4
Specifications of AD261BND-4
Related parts for AD261BND-4
AD261BND-4 Summary of contents
Page 1
... Six models allow all I/O combinations from five input lines to five output lines, including combinations in between. Every AD261 effectively replaces up to five opto-isolators. Each line of the AD261 has a bandwidth of 20 MHz (min) with a propagation delay of only 14 ns, which allows for extremely fast data transmission ...
Page 2
AD261–SPECIFICATIONS Parameter INPUT CHARACTERISTICS Threshold Voltage Positive Transition ( Negative Transition (V ) T– Hysteresis Voltage ( Input Capacitance ( Input Bias Current ( OUTPUT CHARACTERISTICS 1 Output Voltage High Level (V ...
Page 3
... Inputs, 5 Outputs AD261BND-1 1 Input, 4 Outputs AD261BND-2 2 Inputs, 3 Outputs AD261BND-3 3 Inputs, 2 Outputs AD261BND-4 4 Inputs, 1 Output AD261BND-5 5 Inputs, 0 Outputs CAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the AD261 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges ...
Page 4
AD261 AD261-0 LATCH F0 LINE 0 LATCH F1 LINE 1 LATCH F2 LINE 2 LATCH F3 LINE 3 LATCH F4 LINE 4 ENABLE 17 FLD + FLD 5V dc RTN 5V RTN 15 FLD FIELD SYSTEM ...
Page 5
... Power consumption, unlike opto-isolators function of operat- ing frequency. Each logic line barrier driver requires about 160 A * per MHz and each receiver 40 A per MHz plus, of course total idle current (each side). The supply current diminishes ...
Page 6
AD261 Logic information is sent across the barrier as “set-hi/set-lo” data that is derived from logic level transitions of the input. At power-up or after a fault condition, an output might not repre- sent the state of the respective channel ...