ACPL-333J-000E Avago Technologies US Inc., ACPL-333J-000E Datasheet - Page 4

no-image

ACPL-333J-000E

Manufacturer Part Number
ACPL-333J-000E
Description
OPTOCOUPLER IGBT 2.5A 16-SOIC
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ACPL-333J-000E

Output Type
Gate Driver, Miller Clamp
Package / Case
16-SOIC (0.300", 7.50mm Width)
Voltage - Isolation
3750Vrms
Number Of Channels
2, Bi-Directional
Current - Output / Channel
1.5A
Propagation Delay High - Low @ If
180ns @ 10mA
Current - Dc Forward (if)
12mA
Input Type
DC
Mounting Type
Surface Mount
Fall Time
50 ns
Rise Time
50 ns
Configuration
2 Channel
Maximum Forward Diode Voltage
1.95 V
Minimum Forward Diode Voltage
1.2 V
Maximum Reverse Diode Voltage
5 V
Maximum Power Dissipation
600 mW
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACPL-333J-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Regulatory Information
The ACPL-333J is approved by the following organizations:
IEC/EN/DIN EN 60747-5-2
Approval under:
IEC 60747-5-5 :1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01
Table 1. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics*
*
** Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section IEC/EN/
Dependence of Safety Limiting Values on Temperature. (take from DS AV01-0579EN Pg.7)
4
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b**,
V
Input to Output Test Voltage, Method a**,
V
Highest Allowable Overvoltage (Transient Overvoltage t
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
Input Current
Output Power
Insulation Resistance at T
IORM
IORM
for rated mains voltage ≤ 150 V
for rated mains voltage ≤ 300 V
for rated mains voltage ≤ 600 V
for rated mains voltage ≤ 1000V
Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
Surface mount classification is class A in accordance with CECCOO802.
DIN EN 60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles.
x 1.875=V
x 1.6=V
PR
, Type and Sample Test, t
PR
, 100% Production Test with t
S
, V
IO
= 500 V
rms
rms
rms
rms
m
=10 sec, Partial discharge < 5 pC
m
=1 sec, Partial discharge < 5 pC
ini
= 60 sec)
UL
Approval under UL 1577, component recognition
program up to V
CSA
Approval under CSA Component Acceptance Notice #5,
File CA 88324.
Symbol
V
V
V
V
T
I
P
R
S, INPUT
S
IORM
PR
PR
IOTM
S, OUTPUT
S
ISO
= 5000 V
RMS
2
Characteristic
I – IV
I – IV
I – IV
I – III
55/100/21
1230
2306
1968
8000
175
400
1200
>10
. File E55361.
9
Unit
V
V
V
V
qC
mA
mW
:
peak
peak
peak
peak

Related parts for ACPL-333J-000E