2986122 Phoenix Contact, 2986122 Datasheet - Page 10

MEMORY MODULE FOR TRIO UPS

2986122

Manufacturer Part Number
2986122
Description
MEMORY MODULE FOR TRIO UPS
Manufacturer
Phoenix Contact
Type
Memory Moduler
Datasheets

Specifications of 2986122

Accessory Type
IFS-Confstick
Product
Interface Modules
For Use With/related Products
UPS Systems
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
IFS-CONFSTICK
6.4
The 24 V DC connection is made using the "OUT DC 24 V,
+, -" screw connections. The output voltage set upon
delivery is 24 V DC. The output voltage can be set from
22.5 V DC to 29.5 V DC on the potentiometer.
Figure 4
6.5
Figure 5
104103_en_00
No.
1
3
4
No.
8
9
0
4
3
1
Description
100 ... 240 V AC input
24 V DC output, buffered
22.5 ... 29.5 V DC potentiometer
Description
Red LED indicator: Alarm
Yellow LED indicator: Bat.-Mode/Bat.-Charge
Green LED indicator: Power in OK/Overload
Output
LED indicators
)
L
( +
N
( - )
+
+
2 2
O u
1 0
A d
. 5 -
I n p
2 4
0 - 2
t p u
j u s
2 9
V
u t
. 5
4 0
5 A
t D
t
A C
V
V
C
Connection
LED indicators
P o
B a
B a
R e
R e
B a
B a
B a
w e
C o
U P
1 .
2 .
S T
1 .
2 .
t . - C
t . -
m o
t
O v
m o
t t e
P r
In s
In s
P r
t . -
m a
I C
t . - M
S
e s
e s
C h
n f i
t e
r y
x
r i n
e r t
e r t
A l a
M o
t e
O F
e r l
D A
K
O N
A l a
h a
s B
s B
a r g
m i
F
S T
S T
g . -
T A
D A
r m
d e
R 1
R 2
o d
u t t
u t t
+
r g
o a
IC
IC
e
n
O K
T A
r m
S T
o n
o n
K w
K
C u
(D
P C
P o
e
e
d
U P
e fa
a n
> 6
-M
I C
s t o
u lt
it h
d
o d
r t
S
s e
0 .5
K
in
m
)
e
c
4 s
2 0
e c
1
2
1 5
3
1 0
5
10
8
9
The signal outputs are connected via the "Alarm", "Bat.-
Mode", and "Bat.-Charge" terminal blocks. There are three
LED status indicators and three active switching outputs for
function monitoring.
LED OFF
LED ON
LED flashing
10
1
2
3
4
5
6
7
8
9
Key
Description
The UPS is switched off or the UPS
is operating in mains mode, battery
mode is deactivated (remote),
battery management is still active
The UPS is starting mains
operation, for the LED test all LEDs
are switched on and off again once
before the current operating state is
indicated
The UPS is operating in mains
mode, the battery is OK and
charged
The UPS is operating in mains
mode, the battery is OK and is
charging (charge < 85% of nominal
capacity)
The UPS is operating in battery
mode, the battery voltage U
is > 20.4 V
The UPS is operating in battery
mode, the battery is almost flat
(battery voltage U
UPS protection against total
discharge has terminated battery
mode
(battery voltage U
continues indication for a maximum
of 10 hours
The UPS is operating in mains
mode, the battery is faulty
The UPS has been overloaded in
mains mode, the battery is OK and
charged
The UPS has been overloaded in
mains mode, the battery is faulty
TRIO-UPS/1AC/24DC/5
PHOENIX CONTACT
BAT
BAT
= 19.2 V) and
is < 20.4 V)
BAT
10

Related parts for 2986122