APS2012 Tripp Lite, APS2012 Datasheet - Page 2

INVERTR 2000W 12VDC 2OUT W/CHRGR

APS2012

Manufacturer Part Number
APS2012
Description
INVERTR 2000W 12VDC 2OUT W/CHRGR
Manufacturer
Tripp Lite
Series
PowerVerter® APSr
Type
Inverter, UPSr
Datasheets

Specifications of APS2012

Rohs Status
Not applicable
Voltage - Output
120VAC
Voltage - Input
12VDC, 120VAC
Ac Outlets
Hardwire
Connector - Ac Output
None (Hardwire)
Connector - Voltage Input
Terminals, Junction Box
Power - Output Continuous
2000W
Power - Output Surge
4000W
Remote Capability
Yes
Region Utilized
Internationally
Size
16.25" L x 8.50" W x 7.25" H (412.8mm x 215.9mm x 184.1mm)
Features
Auto Power Transfer for UPS Mode, Battery Charger
Weight
40 lbs (18.1kg)
Voltage - Input Connector
Terminals, Junction Box
Configuration
Enclosed
Current, Input
12 VDC
Dimensions
7.25 in. H x 8.5 in. W x 16.25 in. D
Mounting Type
Panel
Number Of Outputs
2
Operation
Switching
Outlet Type
AC
Output
120 VAC @ 25/100 A, 12 VDC @ 25/100 A
Power, Output
2000 W
Primary Type
DC-AC Inverter
Special Features
Remote On/Off
Temperature, Operating
0 to 40 °C
Type Of Inverter
Power
Voltage, Input
120/12 VAC/VDC
Voltage, Output
120, 12 VAC, VDC
Power Rating
2000 W
Output Voltage Rating
120 V
Interface Port
RJ45
Topology
Standby
Ac Output Connector
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
TL221
Specifications
SYSTEM OVERVIEW
Voltage
compatibility
Frequency
compatibility
OUTPUT
Output watts
Output nominal
voltage
Output voltage
regulation
Output frequency
regulation
Outlet quantity /
type
Overload
protection
Continuous output
capacity (watts)
Peak output
capacity (watts)
INPUT
Input connection
type
Input cord length
blackouts and voltage fluctuations for equipment compatible with a one cycle transfer time
2000 watts continuous AC output in inverter mode, 2400 watts continuous AC output in AC mode
Double Boost inverter output supports momentary startup loads up to 200% of the continuous rating for up to 10 seconds
OverPower inverter output supports longer duration overloads to 150% for 1-60 minutes under ideal battery and temperature conditions. (For
best results, utilize OverPower usage for as short of a duration as possible, ensure battery bank and cabling is able to provide full nominal DC
voltage under load and allow inverter/charger to fully cool before and after OverPower usage.)
3-stage, selectable 25/100 amp battery charger with adjustable settings for wet/gel battery types offers fast, reliable battery recharging
Protected hardwire bolt-down input lugs safely accept heavy gauge input wiring from attached battery bank
Protected hardwire output passes 120V line power or inverter output through to connected equipment
Reliability enhanced large-transformer design with secure mounting flanges and protected DC wiring terminals
Moisture-resistant construction enables vehicular or marine operation in high humidity environments
3 position operating mode switch supports "AUTO" mode to enable automatic transfer between DC and AC modes, CHARGE-ONLY to maintain
a full battery charge when AC is present without auto transfer and SYSTEM OFF settings
Set of six front panel LEDs display AC/DC operational modes, overload status, DC voltage level, shutdown status and system fault status
Set of 4 configuration dip switches support wet/gel battery charging profiles, adjustable 135/145V high voltage auto transfer during overvoltages
and selectable 75/85/95/105V AC low voltage auto transfer during brownouts
Set of 4 additional configuration dip switches support 4 levels of charger limiting relative to output load size, a battery equalization program and
battery charger low/high settings
Resettable 25A charger AC input breaker and resettable 20A AC output breaker and automatic 2 speed cooling fan protect the inverter from load
and temperature related failures
Grounding lug properly connects the inverter/charger system to earth ground or vehicle grounding system
Automatic overload and thermal shutoff safely turns off inverter as excessive loads or overheating conditions develop
Front panel remote control connector enables remote off/on switching (requires APSRM4 switch accessory). Optional APSRM4 accessory also
includes user configurable jacks to support inverter shutoff or startup as a vehicle ignition is engaged
Load sensing control dial enables adjustable load threshold required to automatically turn the inverter on and off in DC mode as load conditions
change
12V DC / 120V AC
60 Hz
2000W (continuous) / 4000W (peak)
120V (AC) / 12V (DC Charger)
LINE POWER (AC): Maintains 120V nominal sine wave output from line power source. INVERTER POWER (AC):
Maintains PWM sine wave output voltage of 120 V AC (+/-5%).
60 Hz (+/- 0.3 Hz)
Hardwire
Includes 25A input breaker dedicated to the charging system and 20A output breaker for AC output loads
2000
4000
DC INPUT: Set of 2 DC bolt-down terminals. AC INPUT: Hardwire via built in junction box with cover plate
DC INPUT: User supplies cabling. 4 gauge or larger (see manual). AC INPUT: user supplies hardwire input cabling