Specifications of APS2012

Rohs Status
Not applicable
Voltage - Output
120VAC
Voltage - Input
12VDC, 120VAC
Ac Outlets
Hardwire
Connector - Ac Output
None (Hardwire)
Connector - Voltage Input
Terminals, Junction Box
Power - Output Continuous
2000W
Power - Output Surge
4000W
Remote Capability
Yes
Region Utilized
Internationally
Size
16.25" L x 8.50" W x 7.25" H (412.8mm x 215.9mm x 184.1mm)
Features
Auto Power Transfer for UPS Mode, Battery Charger
Weight
40 lbs (18.1kg)
Voltage - Input Connector
Terminals, Junction Box
Configuration
Enclosed
Current, Input
12 VDC
Dimensions
7.25 in. H x 8.5 in. W x 16.25 in. D
Mounting Type
Panel
Number Of Outputs
2
Operation
Switching
Outlet Type
AC
Output
120 VAC @ 25/100 A, 12 VDC @ 25/100 A
Power, Output
2000 W
Primary Type
DC-AC Inverter
Special Features
Remote On/Off
Temperature, Operating
0 to 40 °C
Type Of Inverter
Power
Voltage, Input
120/12 VAC/VDC
Voltage, Output
120, 12 VAC, VDC
Power Rating
2000 W
Output Voltage Rating
120 V
Interface Port
RJ45
Topology
Standby
Ac Output Connector
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
TL221
Specifications
OVERVIEW
Intended
Application
OUTPUT
Frequency
compatibility
Output watts
Continuous output
capacity (watts)
Peak output
capacity (watts)
Output nominal
voltage
Output voltage
regulation
Output frequency
regulation
Overload
protection
Outlet quantity /
type
INPUT
Supports 120V AC output from a 120V AC line power source or 12V DC battery source
Supports 120V AC output from a 120V AC 16.6 millisecond automatic transfer between line and battery power supports UPS protection
during blackouts and voltage fluctuations for equipment compatible with a one cycle transfer time
2000 watts continuous AC output in inverter mode, 2400 watts continuous AC output in AC mode
Double Boost inverter output supports momentary startup loads up to 200% of the continuous rating for up to 10 seconds
OverPower inverter output supports longer duration overloads to 150% for 1-60 minutes under ideal battery and temperature conditions.
(For best results, utilize OverPower usage for as short of a duration as possible, ensure battery bank and cabling is able to provide full
nominal DC voltage under load and allow inverter/charger to fully cool before and after OverPower usage.)
3-stage, selectable 25/100 amp battery charger with adjustable settings for wet/gel battery types offers fast, reliable battery recharging
Protected hardwire bolt-down input lugs safely accept heavy gauge input wiring from attached battery bank
Protected hardwire output passes 120V line power or inverter output through to connected equipment
Reliability enhanced large-transformer design with secure mounting flanges and protected DC wiring terminals
Moisture-resistant construction enables vehicular or marine operation in high humidity environments
3 position operating mode switch supports "AUTO" mode to enable automatic transfer between DC and AC modes, CHARGE-ONLY to
maintain a full battery charge when AC is present without auto transfer and SYSTEM OFF settings
Set of six front panel LEDs display AC/DC operational modes, overload status, DC voltage level, shutdown status and system fault status
Set of 4 configuration dip switches support wet/gel battery charging profiles, adjustable 135/145V high voltage auto transfer during
overvoltages and selectable 75/85/95/105V AC low voltage auto transfer during brownouts
Set of 4 additional configuration dip switches support 4 levels of charger limiting relative to output load size, a battery equalization program
and battery charger low/high settings
Resettable 25A charger AC input breaker and resettable 20A AC output breaker and automatic 2 speed cooling fan protect the inverter from
load and temperature related failures
Grounding lug properly connects the inverter/charger system to earth ground or vehicle grounding system
Automatic overload and thermal shutoff safely turns off inverter as excessive loads or overheating conditions develop
Front panel remote control connector enables remote off/on switching (requires APSRM4 switch accessory). Optional APSRM4 accessory
also includes user configurable jacks to support inverter shutoff or startup as a vehicle ignition is engaged
Load sensing control dial enables adjustable load threshold required to automatically turn the inverter on and off in DC mode as load
conditions change
Emergency Home Power (Sump Pumps, Furnice Motors, Lighting, Computers & Radio's)
60 Hz
2000
2000
4000
120V
LINE POWER (AC): Maintains 120V nominal sine wave output from line power source. INVERTER POWER (AC):
Maintains PWM sine wave output voltage of 120 V AC (+/-5%).
60 Hz (+/- 0.3 Hz)
Includes 25A input breaker dedicated to the charging system and 20A output breaker for AC output loads