DNET1 Tripp Lite, DNET1 Datasheet - Page 2

SURGE SUPPRESSOR ETHERNET RJ45

DNET1

Manufacturer Part Number
DNET1
Description
SURGE SUPPRESSOR ETHERNET RJ45
Manufacturer
Tripp Lite
Series
DataShield®r
Type
RJ45 (Telephone, Ethernet)r
Datasheets

Specifications of DNET1

Rohs Status
Not applicable
Features
Heavy Duty Grounding Lead
Media Lines Protected
RJ45 (Pins 1-8)
Number Of Outlets
2
Data Line Protection
Y
Output Voltage
230 Volts
Current Rating
750 Amps
Product
Accessories
Current, Rating
750 A (Max.)
Mounting Type
Inline
Number Of Pins
8
Primary Type
Surge Suppressor
Termination
RJ45
Voltage, Clamping
7.5 V
Voltage, Rating
7.5 V
Voltage - Input
-
Power - Max
-
Size
-
Cord Length
-
Ac Outlets
-
Ac Output Connector
-
Ac Input Connector
-
Energy
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With
Data/Comm
Other names
DNET1
TL320
200810167 93-2858.indd 2
1. Make sure the computer, network device or other equipment is logged OFF the network
2. Disconnect the cable from the equipment to be protected.
3. Connect the Data Shield by Tripp Lite Network Dataline Surge Suppressor directly to the
4. Attach the green ground wire on the surge suppressor directly to the protected
5. Reconnect the cable to the Data Shield by Tripp Lite Network Dataline Surge
NOTE!
The Data Shield by Tripp Lite Network Dataline Surge Suppressor must be properly grounded and positioned as close
as possible to the equipment to be protected. For best results, it is required that the length of the signal line and ground
wire (if equipped) between the surge suppressor and the protected equipment be kept as short as possible, not to
exceed 12 inches (12”). It is best to install the surge suppressor directly to the equipment, as noted above.
NOTE!
Installing a typical Data Shield by Tripp Lite Network Dataline Surge Suppressor is equivalent to adding
approximately three feet (3’) of typical data communication cable to a segment.
INSTALLATION
CAUTION!
CAUTION!
CAUTION!
The Data Shield by Tripp Lite Network Dataline Surge
Suppressor does not protect the equipment on the opposite end
of the cable. Normally, protection at both ends is recommended.
Use of this equipment in life support applications where failure
of this equipment can reasonably be expected to cause the
failure of the life support equipment or to significantly affect its
safety or effectiveness is not recommended. Do not use this
equipment in the presence of a flammable anesthetic mixture
with air, oxygen or nitrous oxide.
When properly installed, the Data Shield by Tripp Lite Network
Dataline Surge Suppressor will only protect against surges on
the dataline portion of your installation. Simultaneous AC surge
suppression/power protection in the form of an ISOBAR
suppressor or Tripp Lite UPS system is strongly recommended
for complete system/network protection and can also extend
Ultimate Lifetime Insurance coverage to connected equipment.
(if applicable). Turn OFF power to the equipment.
equipment. DB9 and DB25 models are reversible, to work with male or female ports. To
change gender, remove the thumbscrews, reverse their direction and re-install.
equipment’s chassis. (Except DB9 and DB25 models.)
Suppressor.
2
®
surge
12/16/2008 9:58:51 AM