OMNI1000ISO Tripp Lite, OMNI1000ISO Datasheet - Page 3

UPS 1000VA 700W 6OUT USB TOWER

OMNI1000ISO

Manufacturer Part Number
OMNI1000ISO
Description
UPS 1000VA 700W 6OUT USB TOWER
Manufacturer
Tripp Lite
Series
OmniSmart™r
Type
UPSr
Datasheet

Specifications of OMNI1000ISO

Power - Rated
1kVA / 700W
Ac Outlets
6 (UPS)
Features
USB Communication Port
Backup Time - Max Load
8 minutes
Voltage - Output Per Connector
120V
Voltage - Input
120V / 15A
Cord Length
6' (1.83m)
Ac Input Connector
NEMA 5-15P
Connector - Ac Output
NEMA 5-15R
Size
9.25" L x 7.50" W x 12.75" H (235.0mm x 190.5mm x 323.9mm)
Weight
37 lbs (16.8kg)
Ac Output Connector
NEMA 5-15R
Power Rating
700 W
Output Voltage Rating
1000 VA
Number Of Outlets
6
Runtime (full Load)
8 min ( 700 W )
Runtime (half Load)
24 min ( 350 W )
Tower / Rackmount
Tower
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Media Lines Protected
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
DC system voltage (VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery Access
Battery replacement
description
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage correction
Undervoltage correction
Severe undervoltage
correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel operation
Switches
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
UPS AC suppression
response time
EMI / RFI AC noise
suppression
ISOLATION
Output isolation
transformer
Surge voltage withstand
capability
Surge voltage attenuation
Insertion loss
PHYSICAL
Installation form factors
supported with included
accessories
Installation form factors
supported with optional
accessories
Primary form factor
36
Less than 4.5 hours from 10% to 90%
RBC53
Battery access door
Hot-swappable, user replaceable batteries
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 85 to 143
Input voltages between 128 and 143V are reduced by 9%
Input voltages between 96 and 107V are boosted by 10%
Input voltages between 85 and 95V are boosted by 20%
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Audible alarm indicates power-failure and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
2 Switches control off/on power status and alarm-cancel/self-test operation
510
Instantaneous
Yes
Professional grade load isolation transformer
ANSI/IEEE C62.41 Categories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave
N-G 2000:1, L-G 240:1, L-N 100:1
65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500
Khz
Tower
Wallmount (UPSWM - tower mounting kit)
Tower