SMART750RMXL2U Tripp Lite, SMART750RMXL2U Datasheet - Page 3

UPS SMARTPRO 750VA 450W 6OUT

SMART750RMXL2U

Manufacturer Part Number
SMART750RMXL2U
Description
UPS SMARTPRO 750VA 450W 6OUT
Manufacturer
Tripp Lite
Series
Smart Pro®r
Type
Power Supply Regulatorr
Datasheet

Specifications of SMART750RMXL2U

Power - Rated
750VA / 450W
Ac Outlets
6 (UPS)
Backup Time - Max Load
16 minutes
Voltage - Output Per Connector
120V
Voltage - Input
120V / 15A
Cord Length
10' (3.05m)
Ac Input Connector
NEMA 5-15P
Connector - Ac Output
NEMA 5-15R
Size
14.25" L x 17.50" W x 3.50" H (362.0mm x 444.5mm x 88.9mm)
Weight
35 lbs (15.9kg)
Ac Output Connector
NEMA 5-15R
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
-
Media Lines Protected
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
UPS input connection type
Input circuit breaker
UPS Input cord length (ft.)
Recommended Electrical
Service
Input cord length (ft.)
Input cord length (m)
BATTERY
Full load runtime (minutes)
Half load runtime
(minutes)
Expandable battery
runtime
External battery pack
compatibility
DC system voltage (VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery Access
Battery replacement
description
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage correction
Undervoltage correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel operation
Switches
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
EMI / RFI AC noise
suppression
AC suppression joule
rating
5-15P
15A
10 ft / 3m
15A 120V
10
3
12.5 min. (450w)
30 min. (225w)
Extended runtime supported via optional external battery packs
BP24V15RT2U
24
Less than 4 hours from 10% to 90%
RBC92-2U
Front panel battery access door
Hot-swappable, user replaceable batteries
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
Input voltages between 128 and 147 are reduced by 12%
Input voltages between 83 and 107 are boosted by 14%
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Audible alarm indicates power-failure, overload and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
2 Switches control off/on power status and alarm-cancel/self-test operation
480 joules
Yes
480
(limit 1);
BP24V28-2U
(limit 1);
BP24V70-3U
(multi-pack compatible)

Related parts for SMART750RMXL2U