SU3000XL Tripp Lite, SU3000XL Datasheet - Page 3

no-image

SU3000XL

Manufacturer Part Number
SU3000XL
Description
UPS 3KVA 2400W 7OUT SERIAL
Manufacturer
Tripp Lite
Series
Smart Online™r
Type
UPSr
Datasheets

Specifications of SU3000XL

Power - Rated
3kVA / 2400W
Ac Outlets
7 (UPS)
Features
DB9 and USB Communications, SNMP Card Slot
Backup Time - Max Load
6 minutes
Voltage - Output Per Connector
120V (6 NEMA 5-15/20R and 1 NEMA L5-30R)
Voltage - Input
208V / 30A
Cord Length
10' (3.05m)
Ac Input Connector
NEMA L5-30P
Connector - Ac Output
6 NEMA 5-15/20R and 1 NEMA L5-30R
Size
20.50" L x 9.00" W x 10.25" H (520.7mm x 228.6mm x 260.4mm)
Weight
69 lbs (31.3kg)
Ac Output Connector
6 NEMA 5-15/20R and 1 NEMA L5-30R
Brand/series
SmartOnline™
Capacity
3000 VA
Color
Black
Communication
DB9, RJ45, RS232, USB
Current, Rating
24.6 A (Max.)
Dimensions
26cmH×22.9cmW×52.1cmD
Frequency, Output
50⁄60 Hz
Input Type
NEMA L5-30P
Length, Cord
10 ft.
Mounting Type
Rack/Tower
Operation
Online, Double Conversion
Output Type
(4) NEMA 5-15R, (4) NEMA 5-15/20R, (1) NEMA L5-30R
Power, Rating
2400 W
Standards
cUL, UL Listed
Temperature, Operating
0 to +40 °C
Time, Backup
5 min.
Voltage Regulation
2% of 120 V (Maintains Full-Time Sine Wave Output)
Voltage, Battery
72 VDC
Voltage, Input
120
Voltage, Nominal
120 VAC (Output)
Voltage, Output
120 VAC
Voltage, Supply
2400/3000 W/VA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Media Lines Protected
-
Lead Free Status / Rohs Status
RoHS Compliant part
Built-in controllable
switched load banks
Output circuit breaker
Output AC waveform
(AC mode)
Output AC waveform
(battery mode)
INPUT
Rated input current (at
maximum load)
Nominal Input
Voltage(s) Supported
UPS input connection
type
Input circuit breaker
UPS Input cord length
(ft.)
UPS Input cord length
(m)
Recommended
Electrical Service
BATTERY
Full load runtime
(minutes)
Half load runtime
(minutes)
Expandable battery
runtime
External battery pack
compatibility
DC system voltage
(VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery Access
Battery replacement
description
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage correction
Undervoltage
correction
Two switchable four-outlet load banks, (bank 1 - four 5-15/20R, bank 2 - four 5-15R outlets)
15A branch rated breaker (x2) protects 4 outlets each, L5-30R outlet is unbreakered
Pure Sine wave
Pure Sine wave
24A (120V)
110V AC; 120V AC
L5-30P
40A
10
3
30A 120V
5 min. (2400w)
14 min. (1200w)
Extended runtime supported via optional external battery packs
BP72V15-2U
72
Less than 6 hours from 10% to 80%
RBC96-3U
Front panel battery access door
Hot-swappable, user replaceable batteries
Online, double-conversion power conditioning
2% output voltage regulation during overvoltages to 150
2% output voltage regulation during undervoltages to 80
(limit 1);
BP72V28RT-3U
(multi-pack compatible)

Related parts for SU3000XL