SU3000RTXL3UHV Tripp Lite, SU3000RTXL3UHV Datasheet - Page 3

UPS 3KVA 2400W 8OUT RACK MOUNT

SU3000RTXL3UHV

Manufacturer Part Number
SU3000RTXL3UHV
Description
UPS 3KVA 2400W 8OUT RACK MOUNT
Manufacturer
Tripp Lite
Series
Smart Online™r
Type
Power Supply Regulatorr
Datasheet

Specifications of SU3000RTXL3UHV

Power - Rated
3kVA / 2400W
Ac Outlets
8 (UPS)
Features
DB9 Communications, SNMP Card Slot
Backup Time - Max Load
6 minutes
Voltage - Output Per Connector
208V (200, 208, 230, 220, 240V)
Voltage - Input
200 ~ 240V / 15A
Cord Length
10' (3.05m)
Ac Input Connector
NEMA L6-20P
Connector - Ac Output
6 NEMA 6-15/20R and 2 NEMA L6-20R
Size
19.80" L x 17.30" W x 5.20" H (502.9mm x 439.4mm x 132.1mm)
Weight
50 lbs (22.7kg)
Ac Output Connector
6 NEMA 6-15/20R and 2 NEMA L6-20R
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Media Lines Protected
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Input circuit breaker
UPS Input cord length
(ft.)
UPS Input cord length
(m)
Recommended
Electrical Service
BATTERY
Full load runtime
(minutes)
Half load runtime
(minutes)
Expandable battery
runtime
External battery pack
compatibility
DC system voltage
(VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal
UPS battery
replacement)
Battery Access
Battery replacement
description
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage
correction
Undervoltage
correction
Severe undervoltage
correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel
operation
Switches
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
25A double pole
10
3
20A
5 min. (2400w)
14 min. (1200w)
Supports extended runtime with optional external battery packs
BP72V15-2U
72
Less than 6 hours from 10% to 80%
RBC53
Front panel battery access door
Hot-swappable, user replaceable batteries
Online, double-conversion power conditioning
Maintains output during overvoltages to 275
Maintains output during undervoltages to 160V AC
At load levels less than 70%, UPS maintains output during undervoltages to 130V AC
14 LEDs indicate line power, online mode, bypass mode, on-battery, overload, battery low, replace battery and fault
status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in
rack/tower formats
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown
conditions
Power-fail alarm can be silenced using alarm-cancel switch
2 switches control off/on power status and alarm-cancel/self-test operation
2670
(quantity 2)
(limit 1);
BP72V28RT-3U
(multi-pack compatible)

Related parts for SU3000RTXL3UHV