SU5000RT3UHV Tripp Lite, SU5000RT3UHV Datasheet - Page 5

UPS SMARTONLINE 5KVA 3500W 4OUT

SU5000RT3UHV

Manufacturer Part Number
SU5000RT3UHV
Description
UPS SMARTONLINE 5KVA 3500W 4OUT
Manufacturer
Tripp Lite
Series
Smart Online™r
Type
Power Supply Regulatorr
Datasheet

Specifications of SU5000RT3UHV

Power - Rated
5kVA / 3500W
Ac Outlets
4 (UPS)
Features
EPO Jack, SNMP Card Slot
Backup Time - Max Load
8 minutes
Voltage - Output Per Connector
208/120 or 240/120V (2 NEMA L6-30R and 2 NEMA L6-20R )
Voltage - Input
208V / 30A
Cord Length
10' (3.05m)
Ac Input Connector
NEMA L6-30P
Connector - Ac Output
2 NEMA L6-30R and 2 NEMA L6-20R
Size
17.50" L x 22.50" W x 3.50" H (444.5mm x 571.50mm x 88.9mm)
Weight
42 lbs (19.1kg)
Ac Output Connector
2 NEMA L6-30R and 2 NEMA L6-20R
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Media Lines Protected
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Shipping weight (kg)
UPS housing material
Cooling method
ENVIRONMENTAL
Operating Temperature
Range
Storage Temperature
Range
Relative Humidity
AC mode BTU / hr. (full
load)
AC economy mode
BTU / hr. (full load)
Battery mode BTU / hr.
(full load)
AC economy mode
efficiency rating (100%
load)
COMMUNICATIONS
Communications
interface
Network monitoring
port description
PowerAlert software
Communications cable
LINE / BATTERY TRANSFER
Transfer time
Low voltage transfer to
battery power (setpoint)
High voltage transfer to
battery power (setpoint)
SPECIAL FEATURES
Cold Start (startup in
battery mode during a
power failure)
High availability UPS
features
Green & high efficiency
features
CERTIFICATIONS
UPS Certifications
WARRANTY
Product Warranty
Period (U.S., Canada &
Puerto Rico)
89
Steel
Fan
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
0 to 95%, non-condensing
1322.2
759.6
1322.2
94%
DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
RS232 and contact closure communications are located on two separate DB9 ports
Included
DB9 cable included
No transfer time (0 ms.) in online, double-conversion mode
156
276
Cold-start operation supported
Automatic inverter bypass; Hot swappable batteries
High efficiency economy mode operation; Schedulable daily hours of economy mode operation
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to CE (EU); Tested to
GOST (Russia); Tested to SASO (Saudi Arabia); Meets FCC Part 15 Category A (EMI)
2-year limited warranty