Specifications of SU10K3/1X

Power - Rated
10kVA / 8000W
Backup Time - Max Load
6 minutes
Voltage - Output Per Connector
220, 230, 240V (3 phase)
Voltage - Input
220, 230 or 240V / 15A (3 phase)
Ac Input Connector
Hardwire
Connector - Ac Output
None (Hardwire)
Size
24.80" l x 11.00" W x 22.20" H (629.9mm x 279.4mm x 563.9mm)
Weight
102 lbs (46.3kg)
Ac Output Connector
Hardwire
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Cord Length
-
Ac Outlets
-
Media Lines Protected
-
Expandable battery
runtime
External battery pack
compatibility
DC system voltage
(VDC)
Battery recharge rate
(included batteries)
Battery replacement
description
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage
correction
Undervoltage
correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel
operation
Switches
SURGE / NOISE SUPPRESSION
UPS AC suppression
response time
EMI / RFI AC noise
suppression
AC suppression
response time
PHYSICAL
Installation form
factors supported
with included
accessories
Primary form factor
UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / inches)
UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / cm)
Supports extended runtime with optional external battery packs
BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH;
240
2 - 4 hours from 10% to 90%
Hot-swappable, user replaceable batteries
Online, double-conversion power conditioning
Maintains continuous operation without using battery power during overvoltages to 485 (Y, 3-Phase, 4 Wire),
reducing output within 2% of selected nominal
Maintains continuous operation without using battery power during brownout / undervoltage conditions to 270 (Y,
3-Phase, 4 Wire)
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD
screen offers additional information and control options
Alarms warn against a variety of operational conditions: low-battery, overload, shutdown, bypass and more
Power-fail alarm can be silenced using alarm-cancel switch
Rocker switch turns the UPS's inverter ON and OFF. "Select" Button browses through and selects items displayed
on the LCD screen. "Battery Start" Switch cold starts the inverter. "Manual Bypass" switch bypasses the UPS's
inverter during maintenance.
Instantaneous
Yes
Instantaneous
Tower
Tower
22.2 x 11 x 24.8
56.4 x 27.9 x 63
BP240V1407C-1PH