LCD MOD GRAPHIC 240X128 TRANSM

NHD-240128WG-AFTI-VZ#C5

Manufacturer Part Number
NHD-240128WG-AFTI-VZ#C5
Description
LCD MOD GRAPHIC 240X128 TRANSM
Manufacturer
Newhaven Display
Datasheet

Specifications of NHD-240128WG-AFTI-VZ#C5

Display Type
FSTN - Film Super-Twisted Nematic
Display Mode
Transmissive
Viewing Area
129.00mm L x 75.00mm W
Backlight
CCFL - White
Dot Size
0.47mm W x 0.47mm H
Dot Pitch
0.50mm x 0.50mm
Dot Pixels
240 x 128
Interface
Parallel
Pixel Density
240 x 128
Fluid Type
FSTN Negative
Module Size (w X H X T)
170 mm x 103.5 mm x 14 mm
Backlighting
LED White
Operating Temperature Range
- 20 C to + 70 C
Product
Graphic LCD Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
11.Reliability
Content of Reliability Test (wide temperature, -20 ~70 )
Note1: No dew condensation to be observed.
Note2: The function test shall be conducted after 4 hours storage at the normal
Note3: Vibration test will be conducted to the product itself without putting it in a container.
High Temperature
storage
Low Temperature
storage
High Temperature
Operation
Low Temperature
Operation
High Temperature/
Humidity Operation
Thermal shock
resistance
Vibration test
Static electricity test
Test Item
Temperature and humidity after remove from the test chamber.
Endurance test applying the high storage temperature
for a long time.
Endurance test applying the high storage temperature
for a long time.
Endurance test applying the electric stress (Voltage &
Current) and the thermal stress to the element for a
long time.
Endurance test applying the electric stress under low
temperature for a long time.
The module should be allowed to stand at 60
For 96hrs under no-load condition excluding the
polarizer,
Then taking it out and drying it at normal temperature.
The sample should be allowed stand the following 10
cycles of
operation
-20
30min
1 cycle
Endurance test applying the vibration during
transportation and using.
Endurance test applying the electric stress to the
terminal.
,90%RH max
5min
25
Environmental Test
Content of Test
30min
70
80
200hrs
-30
200hrs
70
200hrs
-20
200hrs
60 ,90%RH
96hrs
-20 /70
10 cycles
Total fixed
amplitude : 1.5mm
Vibration
Frequency : 10~55Hz
One cycle 60 seconds
to 3 directions of
X,Y,Z for
Each 15 minutes
VS=800V,RS=1.5k
CS=100pF
1 time
Test Condition
2
1,2
——
1
1,2
——
3
——
Note

Related parts for NHD-240128WG-AFTI-VZ#C5