NHD-C24064WO-ATFH#-3V3 Newhaven Display, NHD-C24064WO-ATFH#-3V3 Datasheet - Page 10
NHD-C24064WO-ATFH#-3V3
Manufacturer Part Number
NHD-C24064WO-ATFH#-3V3
Description
LCD COG GRAPH 240X64 WH TRANSFL
Manufacturer
Newhaven Display
Datasheet
1.NHD-C24064WO-ATFH-3V3.pdf
(10 pages)
Specifications of NHD-C24064WO-ATFH#-3V3
Display Type
FSTN - Film Super-Twisted Nematic
Display Mode
Transflective
Viewing Area
130.20mm L x 37.60mm W
Backlight
LED - White
Dot Size
0.50mm W x 0.50mm H
Dot Pitch
0.03mm x 0.03mm
Dot Pixels
240 x 64
Interface
Parallel/Serial
Pixel Density
240 x 64
Fluid Type
FSTN Positive
Module Size (w X H X T)
142.5 mm x 51.7 mm x 14.9 mm
Backlighting
LED White
Operating Temperature Range
- 20 C to + 70 C
Product
Graphic LCD Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
void data_slave(unsigned int d)
{
CS_Slave = reset;
AO = set; //Data High
delay(1);
WRT = reset;
P1 = d;
delay(1);
WRT = set;
CS_Slave = set;
}
/**************************************************************************************/
Quality Information
High Temperature storage
Low Temperature storage
High Temperature
Operation
Low Temperature
Operation
High Temperature /
Humidity Operation
Thermal Shock resistance
Vibration test
Static electricity test
Note 1: No condensation to be observed.
Note 2: Conducted after 4 hours of storage at 25
Note 3:
Precautions for using LCDs/LCMs
See Precautions at www.newhavendisplay.com/specs/precautions.pdf
Warranty Information and Terms & Conditions
http://www.newhavendisplay.com/index.php?main_page=terms
Test Item
Test performed on product itself, not inside a container.
storage temperature for a long time.
Endurance test applying the low storage
temperature for a long time.
Endurance test applying the electric stress
(voltage & current) and the high thermal
stress for a long time.
Endurance test applying the electric stress
(voltage & current) and the low thermal
stress for a long time.
Endurance test applying the electric stress
(voltage & current) and the high thermal
with high humidity stress for a long time.
Endurance test applying the electric stress
(voltage & current) during a cycle of low
and high thermal stress.
Endurance test applying vibration to
simulate transportation and use.
Endurance test applying electric static
discharge.
Endurance test applying the high
Content of Test
⁰C, 0%RH.
[10]
+80⁰C , 48hrs
‐30⁰C , 48hrs
+70⁰C 48hrs
‐20⁰C , 48hrs
+40⁰C , 90% RH , 48hrs
‐0⁰C,30min ‐> 25⁰C,5min ‐>
50⁰C,30min = 1 cycle
10 cycles
10‐55Hz , 15mm amplitude.
60 sec in each of 3 directions
X,Y,Z
For 15 minutes
VS=800V, RS=1.5kΩ, CS=100pF
One time
Test Condition
Note
2
1,2
2
1,2
1,2
3