GP1FH500TZ Sharp Microelectronics, GP1FH500TZ Datasheet
GP1FH500TZ
Specifications of GP1FH500TZ
Available stocks
Related parts for GP1FH500TZ
GP1FH500TZ Summary of contents
Page 1
... Parameter Symbol Supply voltage Output current 4 (Source current) OH (GP1FH500RZ (Sink current Input voltage (GP1FH500TZ) IN Operating temperature T opr Storage temperature T stg *1 Soldering temperature T sol *1 For 5s (2 times or less) Notice In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc ...
Page 2
... Recommended Operating Conditions (GP1FH500TZ) Parameter Symbol Operating supply voltage Operating transfer rate T *2 NRZ signal, duty 50% Recommended Operating Conditions (GP1FH500RZ) Symbol Parameter Operating supply voltage V CC *3*4 Operating transfer rate T *5 Input optical power level P *3 The above operating transfer rate is the value when NRZ signal, "0101.." continuous signal of duty 50% is transmitted *4 The output (H/L level) of GP1FH500RZ are not fixed constantly when it receivers the modulating light (including DC light, no input light) less than 0 ...
Page 3
... Fig.1 Measuring Method of Optical Output Coupling with Fiber GP1FH500TZ Unit to be measured Vin V GND Note ( 5.0V (State of operating) CC (2) To bundle up the standard fiber optic cable, make it into a loop with the diameter D 10cm or more (The standard fiber optic cable will be specified elsewhere.) Fig ...
Page 4
... Fig.3 Measuring Method of Pulse Response and Jitter GP1FH500TZ Unit to be measured GND Input Input signal 3Mbps biphase mark PRBS signal Parameter Low High delay time High Low delay time Pulse width distortion Low High jitter High Low jitter Notes (1) The waveform write time shall be 4s. But do not allow the waveform to be distorted by increasing the brightness too much ( ...
Page 5
... DC light, no input light) less than 0.1Mbps Fiber optic cable V CC CH1 CH2 Standard transmitter Symbol Input signal t pLH (CH1) t pHL GP1FH500RZ t w Output signal (CH2 :2. GP1FH500TZ/GP1FH500RZ GP1FH500RZ Unit to be measured GND V OUT Tektronix 7834 or 7934 type Oscilloscope pLH pHL 50% 90% 50% ...
Page 6
... The probe for the oscilloscope must be more than 1M 10pF Fiber optic cable V CC Oscilloscope CH1 CH2 Input signal GP1FH500RZ :2.2k ) output SO and less than GP1FH500TZ/GP1FH500RZ GP1FH500RZ Unit to be measured GND V OUT Tektronix 7834 or 7934 type Trigger : CH1 Storage mode Sweep : AUTO/NORM ...
Page 7
Application Circuits NOTICE The circuit application examples in this publication are provided to explain representative applications of SHARP devices and are not intended to guarantee any circuit design or license any intellectual property rights. SHARP takes no responsibility for any ...