LD 271-H OSRAM Opto Semiconductors Inc, LD 271-H Datasheet - Page 7

EMITTER IR 950NM 5MM

LD 271-H

Manufacturer Part Number
LD 271-H
Description
EMITTER IR 950NM 5MM
Manufacturer
OSRAM Opto Semiconductors Inc
Datasheet

Specifications of LD 271-H

Wavelength
950nm
Package / Case
Radial - 2 Lead
Current - Dc Forward (if)
130mA
Radiant Intensity (ie) Min @ If
16mW/sr @ 100mA
Voltage - Forward (vf) Typ
1.3V
Viewing Angle
50°
Orientation
Top View
Mounting Type
Through Hole
Maximum Forward Current
130 mA
Maximum Power Dissipation
220 mW
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 40 C
Lens Shape
Circular
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q62703Q0256
LD 271, LD 271 H, LD 271 L, LD 271 LH
Published by
OSRAM Opto Semiconductors GmbH
Wernerwerkstrasse 2, D-93049 Regensburg
www.osram-os.com
© All Rights Reserved.
The information describes the type of component and shall not be considered as assured characteristics. All typical data
and graphs are basing on sample base, but don't represent the production range. If required, e.g. because of technical
improvements, the typ. data will be changed without any further notice.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
1
2
components
, may only be used in life-support devices or systems
with the express written approval of OSRAM OS.
1
A critical component is a component usedin a life-support device or system whose failure can reasonably be expected
to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system.
2
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
2007-04-04
7

Related parts for LD 271-H