LY T676-R1S2-26 OSRAM Opto Semiconductors Inc, LY T676-R1S2-26 Datasheet - Page 16

LED YELLOW 587NM CLR 2-PLCC SMD

LY T676-R1S2-26

Manufacturer Part Number
LY T676-R1S2-26
Description
LED YELLOW 587NM CLR 2-PLCC SMD
Manufacturer
OSRAM Opto Semiconductors Inc
Series
TOPLEDr
Datasheet

Specifications of LY T676-R1S2-26

Color
Yellow
Luminous Flux @ Current - Test
600 mlm
Millicandela Rating
196mcd
Current - Test
20mA
Wavelength - Dominant
587nm
Wavelength - Peak
591nm
Voltage - Forward (vf) Typ
2V
Lens Type
Clear
Lens Style/size
Round, 2.4mm
Package / Case
2-PLCC
Size / Dimension
3.20mm L x 2.80mm W
Height
2.10mm
Viewing Angle
120°
Mounting Type
Surface Mount
Resistance Tolerance
587nm
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
475-1006-2
LYT676R1S226
Q65110A1417
Published by OSRAM Opto Semiconductors GmbH
Wernerwerkstrasse 2, D-93049 Regensburg
© All Rights Reserved.
Attention please!
The information describes the type of component and shall not be considered as assured characteristics.
All typical data and graphs are basing on representative samples, but don’t represent the production range. If
requested, e.g. because of technical improvements, these typ. data will be changed without any further notice.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
If printed or downloaded, please find the latest version in the Internet.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components
1
to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or
system.
2
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
2002-09-18
Revision History: 2002-09-18
Previous Version: 2002-09-16
Page
4
5
1
2
10
15
4
14
3, 4
1, 4
A critical component is a component used in a life-support device or system whose failure can reasonably be expected
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
Subjects (major changes since last revision)
Value (wavelength amber)
New wavelength grouping
Insert of ESD-withstand voltage
wavelength grouping for yellow and orange
change of weight from 40 mg to 35 mg
annotations
value (
recomm. solder pad for TOPLED
value (reverse voltage from 3 V to 12 V)
typ. wavelength for amber from 617 to 615
1
may only be used in life-support devices or systems
TC
dom
from 0.01 to 0.05 nm/K)
®
and Power TOPLED
16
LS T676, LA T676, LO T676, LY T676
2
with the express written approval of OSRAM OS.
®
(OHLPY440)
2002-09-18
Date of change
2002-06-28
2002-07-25
2002-07-25
2002-08-05
2002-09-12

Related parts for LY T676-R1S2-26