LY W5AM-HYJZ-36-Z OSRAM Opto Semiconductors Inc, LY W5AM-HYJZ-36-Z Datasheet - Page 3

LED DRAGON PLUS YELLOW 590NM SMD

LY W5AM-HYJZ-36-Z

Manufacturer Part Number
LY W5AM-HYJZ-36-Z
Description
LED DRAGON PLUS YELLOW 590NM SMD
Manufacturer
OSRAM Opto Semiconductors Inc
Series
Golden DRAGON® Plusr
Type
Golden DRAGON Plusr

Specifications of LY W5AM-HYJZ-36-Z

Viewing Angle
170°
Color
Yellow
Current - Test
400mA
Luminous Flux @ Current - Test
52lm
Current - Max
1A
Lumens @ Current - Max
116lm
Lumens/watt @ Current - Test
59lm/W
Voltage - Forward (vf) Typ
2.2V
Wavelength
590nm
Lens Style/size
Round, 5mm
Mounting Type
Surface Mount
Package / Case
7.00mm L x 6.00mm W x 2.80mm H
Illumination Color
Yellow
Wavelength/color Temperature
590 nm
Luminous Flux
33 lm to 61 lm
Luminous Intensity
16 cd
Power Rating
1 W
Operating Voltage
2.3 V
Operating Current
400 mA
Minimum Operating Temperature
- 40 C
Maximum Operating Temperature
+ 125 C
Lens Shape
Dome
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
876-1003 - LM3406 LED DRIVER EVAL BOARD
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
475-2836-2
Q65110A8617
For more detailed product information and Technical Datasheets, please visit
Light Emitting Diodes
Safety Instructions
The use of new chip technologies means that OSRAM LEDs are
delivering higher and higher levels of optical performance. Thus, even
eye safety issues might increasingly need to be considered. In general,
the EU product safety legislation requires conformity with EC directives
(such as the "Low Voltage Directive") which define the "essential
requirements", e.g., protection of health and safety, that goods must
meet when they are placed on the market.
We therefore recommend that the current version of the IEC 62471
standard is taken into account right from the outset, i.e. at the equipment
development stage, and that suitable protection facilities are provided in
your laboratories.
Eye Safety Information
The light output of modern High-Power-LEDs is strong enough for eye
irritation and temporal blinding effects. Therefore, in general, do not stare
into the light beam of any LED at close range.
Optical radiation hazards by LED-based lamps, lamp systems or
luminaires have to be assessed and classified according to the
requirements of IEC62471 ("Photobiological safety of lamps and lamp
systems").
Within the risk grouping system of this IEC standard, most LEDs
specified in this catalogue fall into the "exempt" group. However, high-
power "blue" LEDs and the most important "white" LEDs for general
lighting may need some attention. Due to their dominating photochemical
hazard potential, extensive deliberate long-term direct viewing from
close distance can indeed be hazardous. Under worst case conditions of
classification, these high power light sources can even be allocated to
the "moderate risk group" i.e. safety bases on aversion reactions against
bright light. However, under real circumstances (for exposure time, eye
pupils, observation distance), it is assumed that no endangerment to the
eye exists from these devices. This is valid for single LEDs under the
mentioned conditions and operating conditions defined in the data sheet.
Complex Multi-LED-designs, additional optics or extreme application
conditions demand a separate evaluation of the entire system.
As a matter of principle, however, it should be mentioned that intense
light sources have a high secondary exposure potential due to their
blinding effect. As for any bright light source, when viewing into it (e.g.
headlights), temporary reduction in visual acuity and afterimages can
occur, leading to irritation, annoyance, visual impairment, and even
accidents, depending on the situation.
Remarks:
User shall not reverse engineer by disassembling or analysis of the LEDs
without having the prior written consent of OSRAM Opto Semiconductors
GmbH. When defective LEDs are found, user shall inform to OSRAM
Opto Semiconductors GmbH directly before disassembling or analysis.
The appearance and specifications of the product may be modified for
improvement without notice.
For more detailed product information and Technical Datasheets, please visit http://catalog.osram-os.com
Light Emitting Diodes
http://catalog.osram-os.com
Sicherheitshinweise
OSRAM LEDs erreichen aufgrund von neuen Chip-Technologien immer
höhere optische Leistungen. Deshalb müssen auch Sicherheitsaspekte
bezüglich Augensicherheit zunehmend in Betracht gezogen werden.
Generell fordern die EU Produkt-Sicherheitsgesetze Konformität mit den
EU Richtlinien (z.B. die "Niederspannungsrichtlinie"), die wesentliche
Forderungen festlegen, z.B. an Sicherheit und Gesundheitsschutz, die
die auf den Markt gebrachten Produkte erfüllen müssen.
Wir empfehlen daher, schon bei der Entwicklung von Geräten, die zu
diesem Zeitpunkt gültige Norm IEC 62471 zu beachten und
insbesondere auf den Gebrauch von entsprechenden
Schutzvorrichtungen in Ihren Labors hinzuweisen.
Informationen zur Augensicherheit
Die Lichtausbeute der modernen Hochleistung-LEDs ist stark genug, um
Augenreizungen und zeitliche Blindheitseffekte hervorzurufen. Daher
sollten Sie generell nicht aus kurzer Entfernung in den Lichtstrahl
jeglicher LED blicken.
Risiken durch optische Strahlung, die durch LED-basierte Lampen,
Lampen-Systeme oder Leuchter entstehen, müssen eingeschätzt und
nach der Forderungen des IEC62471 Standards ("Photobiological safety
of lamps and lamp systems") bewertet werden.
Im Rahmen des Risikogruppensystems des IEC Standards fallen die
meisten in diesem Katalog beschriebenen LEDs in die "exempt" (befreit)
Gruppe. Jedoch sollten hochleistungsfähige blaue LEDs und die
wichtigsten weißen LEDs näher betrachtet werden. Auf Grund ihres
hohen photochemischen Risiko-Potenzials kann das langfristige,
bewusste, direkte Ansehen gefährlich sein. Bei ungünstigsten
Bedingungen der Anordnung können die Hochleistungs-LEDs sogar der
"moderate risk group" (gemäßigte Risikogruppe) zugeordnet werden,
d.h. die Sicherheit beruht auf Aversions-Reaktionen auf helles Licht.
Unter realen Umständen (in Bezug auf Belichtungszeit, Pupillen,
Betrachtungsabstand) kann jedoch angenommen werden, dass keine
Gefahr für die Augen von diesen Geräten ausgeht. Dies gilt für einzelne
LEDs unter den genannten Konditionen und im Datenblatt definierten
Betriebsbedingungen. Komplexe Multi-LED Designs, zusätzliche Optik
oder außergewöhnliche Anwendungsbedingungen fordern eine
gesonderte Bewertung des ganzen Systems.
Prinzipiell ist jedoch zu erwähnen, dass starke Lichtquellen auf Grund
ihrer Blendwirkung ein hohes, sekundäres Gefahrenpotenzial besitzen.
Wie bei jeder hellen Lichtquelle kann das direkte Anschauen (z.B.
Scheinwerfer) zur Reduzierung der Sehschärfe oder zu Nachbildern
führen, was Reizungen, Irritationen und sogar Unfälle verursachen kann.
Anmerkungen:
Der Anwender darf keinen Ausbau oder Analyse der LEDs vornehmen,
ohne die vorherige schriftliche Zustimmung von OSRAM Opto
Semiconductors GmbH zu haben. Wenn defekte LEDs gefunden
werden, soll der Anwender baldmöglichst OSRAM Opto Semiconductors
GmbH informieren, bevor er einen Ausbau oder eine Analyse vornimmt.
Erscheinungsform und technische Daten des Produktes können zwecks
Verbesserung ohne Benachrichtigung geändert werden.
13

Related parts for LY W5AM-HYJZ-36-Z