LCW CP7P-KQKS-5L7N-35 OSRAM Opto Semiconductors Inc, LCW CP7P-KQKS-5L7N-35 Datasheet - Page 20

LED WARM WHITE 4000K SMD

LCW CP7P-KQKS-5L7N-35

Manufacturer Part Number
LCW CP7P-KQKS-5L7N-35
Description
LED WARM WHITE 4000K SMD
Manufacturer
OSRAM Opto Semiconductors Inc
Series
OSLON SSLr
Datasheet

Specifications of LCW CP7P-KQKS-5L7N-35

Color
White, Neutral
Current - Test
350mA
Luminous Flux @ Current - Test
86.65lm
Current - Max
700mA
Lumens @ Current - Max
141lm
Lumens/watt @ Current - Test
77lm/W
Voltage - Forward (vf) Typ
3.2V
Wavelength
4000K
Lens Style/size
Round, 2.15mm
Viewing Angle
80°
Mounting Type
Surface Mount
Package / Case
3.00mm L x 3.00mm W x 2.23mm H
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
475-2883-2
Q65110A9864
Vorläufige Daten / Preliminary Data
Revision History:
Previous Version:
Patent List
Patent No.
US 6 066 861
US 6 277 301
US 6 245 259
Wegen der Streichung der LED aus der IEC 60825 erfolgt die Bewertung der Augensicherheit nach dem Standard IEC 62471:2006
("photobiological safety of lamps and lamp systems")
Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LED die "exempt"- Gruppe (die die sich im
"sichtbaren" Spektralbereich auf eine Expositionsdauer von 10000s bezieht). Unter realen Umständen (für Expositionsdauer, Augenpupille,
Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefährdung aus.
Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres Gefahrenpotenzial
besitzen. Wie nach dem Blick in andere helle Lichtquellen (z.B. Autoscheinwerfer) auch, können temporär eingeschränktes Sehvermögen
und Nachbilder je nach Situation zu Irritationen, Belästigungen, Beeinträchtigungen oder sogar Unfällen führen.
Due to the cancellation of the LED from IEC 60825, the evaluation of eye safety occurs according to the standard IEC 62471:2006
("photobiological safety of lamps and lamp systems").
Within the risk grouping system of this CIE standard, the LEDs specified in this data sheet fall into the "exempt" group (relating to devices
in the visible spectrum with an exposure time of 10000s). Under real circumstances (for exposure time, eye pupils, observation distance),
it is assumed that no endangerment to the eye exists from these devices.
As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their
blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages
can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation.
Attention please!
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances.
For information on the types in question please contact our Sales Organization.
If printed or downloaded, please find the latest version in the Internet.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will
take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which
we are not obliged to accept, we shall have to invoice you for any costs incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components
may only be used in life-support devices or systems
2010-09-22
Page
all
2, 9
9
4
1
2
1, 14
8
20
1, 17
1
20
1
20
14
Subjects (major changes since last revision)
Preliminary data sheet created
Ordering codes changed OS-IN-2009-050
Forward Voltage Groups added
Forward voltag updated
color reproduction index added
Ordering code added
Additional information
Chromaticity Coordinate Groups (5000 K) corrected
eye safety information added
preconditioning corrected
Typical Luminous Flux, optical efficiency updated
eye safety information updated
Typical Luminous Flux, optical efficiency corrected
eye safety information corrected
approx. weight corrected
2010-09-22
2010-09-09
7) page 21
with the express written approval of OSRAM OS.
20
Date of change
2009-09-15
2009-11-26
2009-11-26
2009-11-26
2009-12-09
2010-02-23
2010-03-01
2010-06-18
2010-08-03
2010-08-03
2010-08-19
2010-08-31
2010-09-09
2010-09-09
2010-09-22
LCW CP7P
6) page 21

Related parts for LCW CP7P-KQKS-5L7N-35