KMS40-3P3 TDK Corporation, KMS40-3P3 Datasheet

PWR SPLY MEDICAL 3.3V 8A 26W

KMS40-3P3

Manufacturer Part Number
KMS40-3P3
Description
PWR SPLY MEDICAL 3.3V 8A 26W
Manufacturer
TDK Corporation
Series
KMr
Type
Medicalr
Datasheets

Specifications of KMS40-3P3

Power Supply Type
Switching (Closed Frame)
Voltage - Output
3.3V
Number Of Outputs
1
Power (watts)
40W
Applications
Medical
Voltage - Input
90 ~ 264VAC
Mounting Type
Through Hole
1st Output
3.3 VDC @ 8A
Size / Dimension
3.5" L x 2.5" W x 1.06" H (89mm x 63.5mm x 27mm)
Power (watts) - Rated
26.4W
Operating Temperature
-25°C ~ 70°C
Efficiency
75%
Approvals
CE, EN, IEC, UL
Line Regulation
0.5%
Load Regulation
1%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
3.3V
Output Current
8A
Power Rating
26.4W
Input Voltage
90V AC To 264V AC / 100V DC To 375V DC
Brand/series
KM Series
Configuration
Encapsulated
Operation
Switching
Output
3.3 VDC @ 80 mA to 8 A
Power, Output
26.4 W
Primary Type
AC-DC
Special Features
High Efficiency
Voltage, Input
90 to 264/100 to 375 VAC/VDC
Voltage, Output
3.3 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
285-1783
KMS403P3

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KMS40-3P3
Manufacturer:
TDK-LAMBDA
Quantity:
253
1 = Output V1 is isolated from output V2
2 = Output V1 is isolated from outputs V2 and V3
Servicing
These products are not customer serviceable. Repairs may only be carried out by TDK-Lambda
Limited or their authorised agents. These products are not authorised for use as critical components in
nuclear control systems, life support systems or equipment for use in hazardous environments without
the express written approval of the Managing Director of TDK-Lambda Limited.
Approval Limitations: Use in North America (AC units only)
When this product is used on 180VAC-250VAC mains with no neutral, connect the two live wires to
L(live) and N (neutral) terminals on the input connector. In this instance double pole fusing is required.
High Voltage Warning
Dangerous voltages present within the power supply. The proffesional installer must protect service
personnel from inadvertant contact with these dangerous voltages in the end equipment.
Safety Class of Protection
These products are designed for the following parameters : Material Group IIIb, Pollution Degree 2,
Overvoltage Category II, Class II, Indoor use as part of an overall equipment such that the product is
accessible to service engineers only.
Important safety instructions
Output Parameters
Model
KMS40-3P3
KMS40-5
KMS40-9
KMS40-12
KMS40-15
KMS40-24
KMD40-55
KMD40-512
KMD40-524
KMD40-1212
KMD40-1515
KMT40-51212
KMT40-51515
Input Parameters
RATED INPUT VOLTAGE RANGE
RATED INPUT CURRENT (max)
INRUSH CURRENT (240VAC)
INPUT FREQUENCY
KM40 Series Handbook
Output Voltage (V)
3.3V
5V
9V
12V
15V
24V
+5V
-5V
5V (1)
12V (1)
5V (1)
24V (1)
+12V
-12V
+15V
-15V
5V (2)
+12V
-12V
5V(2)
+15V
-15V
Maximum Current (A)
8.00A
8.00A
4.44A
3.33A
2.67A
1.67A
4A
4A
5A
1.25A
5A
0.625A
1.66A
1.66A
1.33A
1.33A
5A
0.6A
0.6A
5A
0.5A
0.5A
20A Max (25°C, COLD START)
100 - 240V AC
47- 63Hz
0.8A,
Power (W)
26.4W
40W
40W
40W
40W
40W
40W
40W
40W
40W
40W
40W
40W
Pin
1
2
3
4
5
6
7
UL/CSA/IEC/EN60601-1, Class II
CE marking when applied to any KM40 series product, indicates cpompliance to the low voltage
directive 2006/95/EC in that it complies with EN60950-1
Operation
Temperature:
Humidity:
Storage and Transportation
Temperature: -40
Humidity: 20% to 95% RH, non-condensing
Shock
<196.1 m/s
Vibration
23.52 m/s
Cooling
Convection, over temperature protected ~ 100
Dielectric Strength testing is carried out as follows:
Primary mains circuits to secondary -4kVAC.
Fuse Information
Fuse
Internal fuse (F1): T3.15AL/250V- Not serviceable
Pin Designations
Level of insulation
Safety approvals
Environmental parameters
Single O/P
AC (L)
AC (N)
+DC
No pin
-DC
No Pin
No Connection
2
2
(10-55H
(20G)
-25
temperature
20 to 95% RH, non-condensing
0
C to +100
Z
0
): constant sweep 1 min X , Y, Z for one hour)
C to +70
0
C
0
C derate linearly to 50% load from 50V
Function Dual
O/P
AC (L)
AC (N)
+DC
No Pin
GND
No Pin
-DC
0
C case temperature
5S/12&24SS
AC (L)
AC (N)
+O/P2
+O/P1
GND1
GND2
No Connection
0
C to 70
0
C max case
Triple O/P
AC (L)
AC (N)
+DC
+5V
GND
+5V GND
-DC
The KM40 family of component power supplies is designed for use within other equipment or
enclosures which restrict access to authorised competent personnel only. For safe installation and
operation of this product, carefully follow the instructions listed below.
i) These products are supplied fully encapsulated
ii) These products are Class II and must be installed in accordance with Class II requirements of
IE/EN/UL/CSAC60601-1
iii) These products are IPX0, and therefore chemicals/solvents, cleaning agents and other liquids
must not be used.
i) These products are designed for continuous operation within an overall enclosure, and must
be mounted such that access to the mains terminals is restricted. See Clause 16, IEC/EN/UL/
CSA60601-1,
ii) These products are NOT suitable for use in the presence of fl ammable anaesthetic mixtures with
air or with oxygen or with nitrous oxide.
iii) These products are classed as ordinary equipment according to IEC/EN/UL/CSA60601-1 and are
NOT protected against the ingress of water.
iv) Connect only apparatus complying with IEC/EN/UL/CSA60601-1 to the signal ports.
v) Except for permanently installed equipment as defi ned in Clause 57.6 of IEC/EN/UL/CSA60601-1,
the overall equipment in which these products are installed must have double pole fusing on the input
mains supply or DC supply as appropriate. The products themselves have single pole fusing in the
live line or positive DC line as appropriate.
vi) Reference should be made to local regulations concerning the disposal of these products at
General installation instructions
Special instructions for medical applications (IEC/EN/UL/CSA60601-1)
KM40 Mechanical Outline Drawing
Part No 17167 Issue 3 July 2008
TDK-Lambda UK Limited,
Kingsley Avenue,
Ilfracombe,
Devon. EX34 8ES.
Telephone - Sales and Service (01271) 856666
Head Offi ce and Works (01271) 856600
Facsimile (01271)864894
WEBSITE: www.uk.tdk-lambda.com
Part Number 17167

Related parts for KMS40-3P3