TWR-5/3000-15/500-D48A-C Murata Power Solutions Inc, TWR-5/3000-15/500-D48A-C Datasheet - Page 8

CONV DC/DC TRI OUT 5,15,-15V

TWR-5/3000-15/500-D48A-C

Manufacturer Part Number
TWR-5/3000-15/500-D48A-C
Description
CONV DC/DC TRI OUT 5,15,-15V
Manufacturer
Murata Power Solutions Inc
Series
TWR Ar
Type
Isolatedr
Datasheet

Specifications of TWR-5/3000-15/500-D48A-C

Number Of Outputs
3
Output
5V, ±15V
Power (watts)
20W
Mounting Type
Through Hole
Voltage - Input
18 ~ 75V
Package / Case
8-DIP Module (7 Leads)
1st Output
5 VDC @ 3A
2nd Output
15 VDC @ 500mA
3rd Output
-15 VDC @ 500mA
Size / Dimension
2.00" L x 2.00" W x 0.45" H (50.8mm x 50.8mm x 11.4mm)
Power (watts) - Rated
20W
Operating Temperature
-40°C ~ 100°C
Efficiency
82%
Approvals
cUL, EN, UL
Output Power
15 W
Input Voltage Range
18 V to 75 V
Input Voltage (nominal)
48 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
3 A
Output Voltage (channel 2)
15 V
Output Current (channel 2)
500 mA
Output Voltage (channel 3)
+/- 15 V
Isolation Voltage
1.5 KV
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1831-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TWR-5/3000-15/500-D48A-C
Manufacturer:
MURATA
Quantity:
21
There are several operational details of the 20W TWR series to be
aware of when applying these converters.
20 Watts maximum power
The total maximum power for all outputs is 20 Watts. This is the
sum of each separate output. Any one output may achieve its
maximum power as long as the sum of all outputs for the whole
converter does not exceed 20 Watts.
For example, using model TWR-5/3000-15/500-D12A, if the maxi-
mum power is drawn from the two ±15 Volt supplies, this produces
15 Watts (7.5 W plus 7.5 W) total power. The 5V output may then
deliver 5 Watts maximum (not 15W) so that the total converter
power is 7.5W+7.5W+5W=20W.
Regulation Differences Between Outputs
Looking at the Schematic diagram, observe that magnetic energy
driven from the primary side affects all three outputs simultane-
ously since they share a common transformer in combination a with
magnetically coupled output inductor. We see that the regulation
feedback is derived directly from the 5 Volt output and indirectly
from the 12/15V outputs. Increasing current on the 12/15V outputs
absorbs magnetic energy driving the 5V output therefore reduc-
ing the 5V output voltage. Regulation compensates for this drop in
output voltage but not to the same extent as the 5V output regula-
tion.
Short-circuit Conditions
Because of the interconnected regulation and common transformer,
a short circuit on one output will cause a voltage reduction on the
remaining unshorted outputs. This effect is more pronounced for
the 5V superior output vs. the 12/15V subordinate outputs. That is, a
5V short essentially places the PWM controller in power-limit mode
whereas a 12/15V short may leave some partial power available on
the remaining outputs.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
20 Watt Converter Operational Details
www.murata-ps.com
© 2008 Murata Power Solutions, Inc.
ISO 9001 REGISTERED
DS-0326A
02/07/08
USA:
Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com
UK:
France:
Germany: München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com
Japan:
China:
Time limits on short circuits
The 5V output will tolerate 5 minutes maximum short circuit time
at +25 deg.C. For the 12/15V outputs, short ciruits must limit to 30
seconds at +25 deg.C. Failure to remove the short circuits within
these time limits may damage the converter or cause permanent
operational changes. Higher ambient temperatures require reduced
short circuit times. As long as shorts or overcurrents are removed
within these time limits, the outputs will automatically recover to
normal operation.
As a practical matter, since it is difficult to control short circuit
duration, make sure that the application is highly unlikely to cause
a short circuit or the input is disconnected by means of a circuit
breaker or fuse.
The Three Outputs are not isolated from each other
The three outputs share a common ground return which is fully
isolated from the primary input side but not between each other.
Therefore do not apply the outputs to applications which require
isolation between the 5V and 12/15V sections.
Tucson (Az), Tel: (800) 547 2537, email: sales@murata-ps.com
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com
Website: www.murata-ps.jp
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel:
20W, Triple Output DC/DC Converters
TWR A-Series
MDC_TWR20W.B03
+1 508 339 3000
Page 8 of 8

Related parts for TWR-5/3000-15/500-D48A-C