HHS60ZE-NT POWER ONE, HHS60ZE-NT Datasheet
![CONV DC-DC 48V IN 3.3V OUT 198W](/photos/8/63/86379/hhs60ze-nt_sml.jpg)
HHS60ZE-NT
Specifications of HHS60ZE-NT
Available stocks
Related parts for HHS60ZE-NT
HHS60ZE-NT Summary of contents
Page 1
... The HHS60 employs 100% surface-mount components for consistency and reliability in our production process, and is available in four standard output voltages from 1.5 to 3.3 VDC. Model Selection Model Input Voltage VDC HHS60ZE 36-75 HHS60ZD 36-75 HHS60ZB 36-75 HHS60ZA 36-75 This product is intended for integration into end-use equipment ...
Page 2
... Input voltage Operating Temperature Storage Temperature ON/OFF Control Voltage 1 O Max 115 C for model: HHS60ZE. BP Environmental, Mechanical & Reliability Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Operating Temperature Operating Humidity Storage Humidity ...
Page 3
Input Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Input Voltage Turn-On Input Voltage Turn-Off Input Voltage Input Reflected Ripple Current Inrush Transient 1 Refer to Fig. 9 for waveform. 2 ...
Page 4
Protections Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Type Threshold Short Circuit Type Threshold Type Threshold Recovery 1 2 See Fig. 13 See Fig. 14 Feature Specifications All specifications apply ...
Page 5
... Efficiency Characteristics 36V Output current, A Figure 1. HHS60ZE, (3.3V) Efficiency Curves 36V Output current, A Figure 2. HHS60ZD (2.5V) Efficiency Curves 36V Output current, A Figure 3. HHS60ZB (1.8V) Efficiency Curves JUN 06, 2006 revised to JUL 25, 2006 HHS60 DC-DC Series Data Sheet 48VDC Input, 60 Amp Half-Brick Converter ...
Page 6
... LFM 300 LFM 400 LFM 200LFM (Tbp @ 115C Ambient Temperature (Deg C) Figure 5. HHS60ZE, (3.3V) Derating Curves The customer may elect to operate the HHS60ZE 115 C thereby extending the operating BP current ratings as defined by the “200 LFM @ O C” derating curve above. This condition T ...
Page 7
... The connector, a 0.1 μF ceramic capacitor and a 10 μF tantalum capacitor, and the load are located 2-3” away from the converter. Page P-P Figure 11. HHS60ZE Output Ripple Characteristics Vin=48V and Iout=3A COPPER STRIPS ( inches) +Vo1 0.1uf 10uF ceramic ...
Page 8
... In a fault condition the converter limits its output voltage and latches off. Figure 14 shows operation of the converter under an overvoltage condition. Figure 14. Output Voltage of an HHS60ZE Under a Forced Overvoltage Condition, Vin=75V, Min Load, Co=none JUN 06, 2006 revised to JUL 25, 2006 HHS60 DC-DC Series Data Sheet ...
Page 9
... Vo*(100-Δ%)-122.5 R trim-dn = R1*(--------------------------- ) - R2 kΩ The 122.5*R1 R trim-up = (------------- - R2) kΩ Where R1 and R2 are constants from the table below Model HHS60ZA HHS60ZB HHS60ZD HHS60ZE Page Vo*Δ% Vo*Δ% R1 (kΩ) R2 (kΩ) 0. 223 0.15 0.474 1 1.039 3.92 4.220 5.11 www.power-one.com ...
Page 10
Optional Positive-Trim (–T, P/N suffix) The trim feature allows the user to adjust the output voltage from its nominal value. The HHS60 positive-trim (-T) models trim up with a resistor from the Trim (#7) pin to the +Sense (#8) pin ...
Page 11
The entire system, including the HHS60 converter, must pass withstand test for Reinforced insulation. Design of this type of systems engineering and under-standing of the overall safety requirements and should be performed by qualified personnel. Thermal Considerations The HHS60 ...
Page 12
Mechanical Drawing Tolerances: .xx + .020 (.5) .xxx + .010 (.25) Pin Diameter + 0.002 (.05) Ordering Information Options Remote ON/OFF Trim Pin Length Special Models Notes NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use ...