VHB200W-Q24-S48 CUI Inc, VHB200W-Q24-S48 Datasheet

no-image

VHB200W-Q24-S48

Manufacturer Part Number
VHB200W-Q24-S48
Description
CONVERTER DC/DC 48V 4.2A 200W
Manufacturer
CUI Inc
Series
V-Infinity VHB200Wr
Type
Isolatedr
Datasheet

Specifications of VHB200W-Q24-S48

Output
48V
Number Of Outputs
1
Power (watts)
200W
Mounting Type
Through Hole
Voltage - Input
10 ~ 36V
Package / Case
9-DIP Module
1st Output
48 VDC @ 4.2A
Size / Dimension
2.40" L x 2.28" W x 0.52" H (61mm x 57.9mm x 13.2mm)
Power (watts) - Rated
200W
Operating Temperature
-40°C ~ 100°C
Efficiency
87%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
102-1986
PART NUMBER: VHB200W
MODEL
VHB200W-Q24-S3R3
VHB200W-Q24-S5
VHB200W-Q24-S12
VHB200W-Q24-S15
VHB200W-Q24-S24
VHB200W-Q24-S28
VHB200W-Q24-S48
VHB200W-Q48-S3R3
VHB200W-Q48-S5
VHB200W-Q48-S12
VHB200W-Q48-S15
VHB200W-Q48-S24
VHB200W-Q48-S28
VHB200W-Q48-S48
notes:
INPUT
parameter
input voltage range
under voltage lockout
remote on/off control
input filter
notes:
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-
date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair
or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty.
description
The VHB200W series of DC-DC converters
are designed for high reliability
applications, featuring over-temperature
protection, and over-current protection.
The wide 4:1 input range (10-36V or
18-75V) is very useful to stabilize an input
source like batteries in various
discharging and charging conditions.
Additionally, high efficiency, fast
response, tight regulations, remote sense
and remote On/Off control make these
converters very useful in many
applications.
20050 SW 112
4
1. see output derating (page 4)
2. input currents are measured at hominal input voltage
3. efficiency is measured at nominal line, full load
4. add suffix “N” to the model number for negative logic on/off control
th
Ave. Tualatin, Oregon 97062
conditions/description
24 Vin power up
24 Vin power down
24 Vin power up (48V output)
24 Vin power down (48V output)
48 Vin power up
48 Vin power down
section 13 in the application notes
PI type
nominal
(V dc)
24
24
24
24
24
24
24
48
48
48
48
48
48
48
input voltage
features
·132-200W isolated output
·Efficiency to 89%
·RoHS Compliant
·4:1 input range
·Regulated output
·Continuous short circuit
·remote on/off
·over-voltage/current protection
·over-temperature shutdown
·industry standard ½ brick size
protection
10.0~36.0
10.0~36.0
10.0~36.0
10.0~36.0
10.0~36.0
10.0~36.0
10.0~36.0
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
(V dc)
range
phone
phone 503.612.2300 fax
DESCRIPTION: half-brick dc-dc converter
voltage
output
(V dc)
3.3
3.3
12
15
24
28
48
12
15
24
28
48
5
5
min
10
18
current
output
16.7
13.3
16.7
13.3
(A)
8.3
7.1
4.2
8.3
7.1
4.2
50
40
40
40
nom
9.5
8.5
9.5
8.5
24
48
17
16
fax 503.612.2382
1
no load
max
(mA)
36
75
150
150
100
100
100
100
100
80
80
60
60
60
60
30
input current
2
full load
7900
9580
9710
9670
9540
6720
3125
4682
4744
4723
4716
4730
(mA)
rev.
page
date
page
date
units
V dc
V dc
V dc
V dc
V dc
V dc
V dc
V dc
2
07/2009
1 of 10
efficiency
typ.
(%)
87
87
86
86
87
87
87
88
89
88
88
88
88
88
3

Related parts for VHB200W-Q24-S48

VHB200W-Q24-S48 Summary of contents

Page 1

... On/Off control make these converters very useful in many applications. MODEL VHB200W-Q24-S3R3 VHB200W-Q24-S5 VHB200W-Q24-S12 VHB200W-Q24-S15 VHB200W-Q24-S24 VHB200W-Q24-S28 VHB200W-Q24-S48 VHB200W-Q48-S3R3 VHB200W-Q48-S5 VHB200W-Q48-S12 VHB200W-Q48-S15 VHB200W-Q48-S24 VHB200W-Q48-S28 VHB200W-Q48-S48 notes: 1. see output derating (page 4) 2. input currents are measured at hominal input voltage 3 ...

Page 2

... PART NUMBER: VHB200W OUTPUT parameter conditions/description voltage accuracy 48V transient response 25% step load change external trim adj. range ripple & noise (20MHz BW) 3 temperature coefficient short circuit protection continuous 5 line regulation 6 load regulation over voltage protection trip range nom. 48V over current protection ...

Page 3

... PART NUMBER: VHB200W MECHANICAL DRAWING th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: half-brick dc-dc converter phone phone 503.612.2300 fax fax 503.612.2382 page date 07/2009 ...

Page 4

... APPLICATION NOTES 1. OUTPUT DE-RATING The operating case temperature range for VHB200W is -40 ~ +100°C. When operating the VHB200W series, proper derating or cooling is needed. The maximum case temperature under any operating condition should not exceed 100°C. Power Dissipated vs Ambient Temperature and Air Flo w Ambient Temperature ,Ta(Deg ...

Page 5

... Ipeak = 150%*Pout/(η η *Vmin). In the previous example of VHB200W-Q24-S5, the peak input current at 10V was calculated to be 34. fuse may be suit- able for this application. Make sure the fuse voltage rating is higher than the maximum input voltage. ...

Page 6

... R load R trim-down FIGURE 5: TRIM-UP VOLTAGE SETUP The value 100 is the Where: R o,nom nominal output voltage and C values are defined in Table 1. For example, to trim- down the 24V module (VHB200W-Q24-S24 25.92V, R Output A B Voltage( 12, 5.11 511 15, 24, 28V 48V 20 2000 phone phone 503 ...

Page 7

... PART NUMBER: VHB200W 8. OUTPUT OCP AND SHORT-CIRCUIT PROTECTION Output overload and short circuit conditional will cause the output voltage to decline or shutdown altogether. is not over 110°C, the output recovers automatically when the short or OCP conditions are removed. In the case of slight overloading, the output voltage may not shut down, but the converter may build up heat over time, causing over-temperature shutdown ...

Page 8

... INPUT FILTERING AND EMI INTERFERENCE The VHB200W converters have input capacitors that control input current ripple and the associated EMI interference. However, it has not been tested to a formal standard for conducted emissions. Additional filtering may be needed to ensure compliance to an EMI standard ...

Page 9

... Class B 82uF/100V KY VHB200W-Q24-S12 Class B 82uF/100V KY VHB200W-Q24-S24 Class B 120uF/100V KY 120uF/100V KY 10uF/50V X7R 2220 VHB200W-Q24-S28 Class A 100uF/100V KY 100uF/100V KY NC VHB200W-Q24-S28 Class B 120uF/100V KY 120uF/100V KY 470uF/100V KY VHB200W-Q24-S48 Class A 100uF/100V KY 100uF/100V KY 100uF/100V KY VHB200W-Q24-S48 Class B 82uF/100V KY VHB200W-Q48-S5 Class B 82uF/100V KY VHB200W-Q48-S12 Class B 120uF/100V KY 120uF/100V KY 4.7uF/100V X7R 2220 1000pF/2KV 680pF/2KV VHB200W-Q48-S24 Class B 120uF/100V KY 120uF/100V KY 4 ...

Page 10

... PART NUMBER: VHB200W 16. OUTPUT FILTERING The converter has built-in capacitors at the output to control ripple and noise. If desired, additional output capacitance can be introduced at the input to the powered equipment. Recommended starting point: one 10μF tantalum and one 1μF ceramic capacitor in parallel at the output. ...

Related keywords