CC15-4805SRH-E TDK Corporation, CC15-4805SRH-E Datasheet - Page 4

CONV DC/DC 48V 5V 3A 15W SMD

CC15-4805SRH-E

Manufacturer Part Number
CC15-4805SRH-E
Description
CONV DC/DC 48V 5V 3A 15W SMD
Manufacturer
TDK Corporation
Series
CC-P-Er
Type
Isolatedr

Specifications of CC15-4805SRH-E

Output
5V
Number Of Outputs
1
Power (watts)
15W
Mounting Type
Surface Mount
Voltage - Input
48V
Package / Case
20-DIP SMD Module (17 Leads)
1st Output
5 VDC @ 3A
Size / Dimension
1.51" L x 1.17" W x 0.27" H (38.4mm x 29.6mm x 6.8mm)
Power (watts) - Rated
15W
Operating Temperature
-40°C ~ 85°C
Efficiency
89%
Approvals
CSA, cUL, EN, UL
Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
36V To 76V
Power Rating
15W
Output Voltage
5V
Output Current
3A
Approval Bodies
CULus, CSA
Supply Voltage
48V
Dc/dc Converter Mounting
SMD
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
3-6 Output Ripple Noise Voltage Measurement Method
When measuring the output ripple noise voltage of this converter, the value differs greatly, depending on the measurement method.
【Caution when Adding External Capacitor Cout】
External capacitor Cout may influence the output ripple voltage by the ESR and ESL and inductance of the wiring. In particular,
caution is required if low ESR ceramic capacitors, etc. are connected, resonance will occur between the capacitor and the wiring
inductance and the ripple component may increase.
※Contact TDK-Lambda concerning items not mentioned or items which are not clear.
Measurement is to be made close to the output terminal, do not make a loop when connecting the probe in order to avoid
picking up magnetic flux. Also, note that the measured value will vary greatly as a result of the frequency band of the ripple
voltmeter or oscilloscope used for measuring. The TDK ripple noise measurement is made according to the method shown in
Figure 3-6.
Input
Oscilloscope
Bw:100MHz
DC
Fig. 3-6 Ripple Noise Voltage Measurement Circuit
R
C
+Vin
-Vin
+Vout
-Vout
JEITA attachment
R=50Ω C=0.1μF
25mm
Cout
3.3V,5V output : Cout=22μF
12V,15V output : Cout=0.1μF
1.5m 50Ω Coaxial Cable
Load

Related parts for CC15-4805SRH-E