DW025AB-M Lineage Power, DW025AB-M Datasheet - Page 12

no-image

DW025AB-M

Manufacturer Part Number
DW025AB-M
Description
CONVERTR DC/DC 5/12V 25W OUT
Manufacturer
Lineage Power
Series
DW025r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of DW025AB-M

Output
5V, 12V
Number Of Outputs
2
Power (watts)
25W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
5 VDC @ 2.5A
2nd Output
12 VDC @ 1.04A
Size / Dimension
2.80" L x 2.40" W x 0.50" H (71.1mm x 61mm x 12.7mm)
Power (watts) - Rated
25W
Operating Temperature
-40°C ~ 100°C
Efficiency
79%
Approvals
CE, CSA, UL, VDE
Product
Isolated
Output Power
13 W
Input Voltage Range
36 V to 75 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
2.5 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
1.04 A
Isolation Voltage
500 V
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
5 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DW025AB-M
Manufacturer:
LUCENT
Quantity:
26
Part Number:
DW025AB-M
Manufacturer:
VECTRON
Quantity:
157
DW025 Dual Output-Series Power Modules: dc-dc Converters;
36 Vdc to 75 Vdc Input; Dual Outputs; 25 W
Thermal Considerations
Note: Dimensions are in millimeters and (inches). Drawing is not to scale.
The 25 W dual output power modules are designed to
operate in a variety of thermal environments. As with
any electronic component, sufficient cooling must be
provided to help ensure reliable operation of the unit.
Heat-dissipating components inside the module are
thermally coupled to the case. Heat is removed by con-
duction, convection, and radiation to the surrounding
environment.
12
CONNECTORS TO
LOADS, POWER
SUPPLIES, AND
6.35 (0.25) TALL
DATALOGGER,
101.6
(4.00)
Figure 15. Thermal Test Setup
203.2 (8.00)
AIRFLOW
12.7 (0.50)
MEASURE CASE
TEMPERATURE AT
CENTER OF UNIT
(2.00)
50.8
The thermal data presented is based on measure-
ments taken in a wind tunnel. The test setup shown in
Figure 15 was used to collect data. Actual performance
can vary depending on the particular application
environment.
203.2
(8.00)
FLOW
AIR-
9.7 (0.38)
19.1 (0.75)
WIND TUNNEL WALL
AIR VELOCITY PROBE
AMBIENT TEMPERATURE
THERMOCOUPLE
Data Sheet
April 2008
Lineage Power
8-866(C).a

Related parts for DW025AB-M