DW025ACL-M Lineage Power, DW025ACL-M Datasheet - Page 2

no-image

DW025ACL-M

Manufacturer Part Number
DW025ACL-M
Description
CONV DC/DC +5/+-15V 25W OUT
Manufacturer
Lineage Power
Series
DW025r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of DW025ACL-M

Output
5V, ±15V
Number Of Outputs
3
Power (watts)
25W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
5 VDC @ 5A
2nd Output
15 VDC @ 830mA
3rd Output
-15 VDC @ 830mA
Size / Dimension
2.80" L x 2.40" W x 0.50" H (71.1mm x 61mm x 12.7mm)
Power (watts) - Rated
25W
Operating Temperature
-40°C ~ 100°C
Efficiency
83%
Approvals
CE, CSA, UL, VDE
Product
Isolated
Output Power
25 W
Input Voltage Range
36 V to 75 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
5 A
Output Voltage (channel 2)
15 V
Output Current (channel 2)
0.83 A
Output Voltage (channel 3)
- 15 V
Output Current (channel 3)
0.83 A
Isolation Voltage
500 V
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
5 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DW025ACL-M
Manufacturer:
LUCENT
Quantity:
26
36 Vdc to 75 Vdc Input; 25 W
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply to all modules over all operating input voltage, resistive load, and
temperature conditions.
Table 1. Input Specifications
* Operation is specified to 75 V, provided the minimum load on Output 1 is at least 0.75 A. Safety agency reports specify 75 V maximum input.
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow, dc fuse with a maximum rating of 5 A in series with the ungrounded input
lead. Based on the information provided in this data sheet on inrush energy and maximum dc input current, the
same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
2 2
Input Voltage Continuous
I/O Isolation Voltage:
Operating Case Temperature
Storage Temperature
Operating Input Voltage
Maximum Input Current
Inrush Transient
Input Reflected-ripple Current, Peak-to-peak
Input Ripple Rejection (120 Hz)
(V
(5 Hz to 20 MHz, 12 µH source impedance;
T
Considerations section.)
dc
Transient (1 minute)
C
I
= 25 °C; see Figure 18 and Design
= 0 V to 75 V; I
Parameter
Parameter
O
= I
O, max
)
Symbol
Symbol
T
T
V
stg
I
C
I, max
I
V
i
2
t
I
Min
36
Min
– 40
– 55
Typ
48
25
60
Max
500
850
100
125
80
Max
72*
2.0
0.2
Lineage Power
April 2008
Unit
Vdc
°C
°C
mAp-p
V
V
Unit
Vdc
A
dB
A
2
s

Related parts for DW025ACL-M