no-image

QW030CL1

Manufacturer Part Number
QW030CL1
Description
CONVERT DC/DC +-15V 30W OUT
Manufacturer
Lineage Power
Series
QWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of QW030CL1

Output
±15V
Number Of Outputs
2
Power (watts)
30W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
8-DIP Module
1st Output
15 VDC @ 1.75A
2nd Output
-15 VDC @ 1.75A
Size / Dimension
2.28" L x 1.45" W x 0.50" H (57.9mm x 36.8mm x 12.7mm)
Power (watts) - Rated
30W
Operating Temperature
-40°C ~ 105°C
Efficiency
88%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
QW030CL1
Manufacturer:
amp
Quantity:
239
18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect device reliability.
* Maximum case temperature varies based on power dissipation. See power derating curves for details.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Table 1. Input Specifications
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal
fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse.
The safety agencies require a normal-blow fuse with a maximum rating of 5 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
2
Input Voltage:
Operating Case Temperature
Storage Temperature
I/O Isolation Voltage
Operating Input Voltage:
Maximum Input Current
Inrush Transient
Input Reflected-ripple Current, Peak-to-peak
Input Ripple Rejection (120 Hz)
(V
(5 Hz to 20 MHz, 12 µH source impedance;
see Test Configurations section.)
(See Thermal Considerations section.)
(Note case is tied to input)
Continuous
Transient (100 ms)
QW030xx
QW030xx
I
= 0 V to 75 V; I
Parameter
Parameter
O
= I
O, max
):
QW030xx
QW030xx
QW030xx
QW030xx
QW030xx
QW030xx
QW030xx
QW030xx
QW030xx
QW030xx
Device
Device
Symbol
Symbol
V
I
I, max
I, trans
T
i
V
Tc
V
2
I
stg
I
t
I
I
Min
36
Min
–40
–55
Typ
48
15
50
1500
105*
Max
100
125
80
Max
2.2
0.2
October 2008
75
Lineage Power
mAp-p
Unit
Vdc
Vdc
°C
°C
Unit
Vdc
V
A
dB
A
2
s